Intraoperative leak testing has no correlation with leak after laparoscopic sleeve gastrectomy.

BACKGROUND: Staple line leak is a serious complication of sleeve gastrectomy. Intraoperative methylene blue and air leak tests are routinely used to evaluate for leak; however, the utility of these tests is controversial. We hypothesize that the practice of routine intraoperative leak testing is unnecessary during sleeve gastrectomy.

METHODS: A retrospective cohort study was designed using a prospectively collected database of seven bariatric surgeons from two institutions. All patients who underwent sleeve gastrectomy from March 2012 to November 2014 were included. The performance of intraoperative leak testing and the type of test (air or methylene blue) were based on surgeon preference. Data obtained included BMI, demographics, comorbidity, presence of intraoperative leak test, result of test, and type of test. The primary outcome was leak rate between the leak test (LT) and no leak test (NLT) groups. SAS version 9.4 was used for univariate and multivariate analyses.

RESULTS: A total of 1550 sleeve gastrectomies were included; most were laparoscopic (99.8%), except for one converted and two open cases. Routine intraoperative leak tests were performed in 1329 (85.7%) cases, while 221 (14.3%) did not have LTs. Of the 1329 cases with LTs, there were no positive intraoperative results. Fifteen (1%) patients developed leaks, with no difference in leak rate between the LT and NLT groups (1 vs. 1%, p = 0.999). After adjusting for baseline differences between the groups with a propensity analysis, the observed lack of association between leak and intraoperative leak test remained. In this cohort, leaks presented at a mean of 17.3 days postoperatively (range 1-67 days). Two patients with staple line leaks underwent repeat intraoperative leak testing at leak presentation, and the tests remained negative.

CONCLUSION: Intraoperative leak testing has no correlation with leak due to laparoscopic sleeve gastrectomy and is not predictive of the later development of staple line leak.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app