Intraoperative radiography for evaluation of surgical miscounts.

PURPOSE: Retained surgical items result in substantial morbidity, health care-related expense, and legal liability. This study determines the performance of a protocol for locating surgical items after a miscount, in which intraoperative radiography included a radiograph of the unaccounted for item.

METHODS: Institutional review board approval was obtained. In 20,820 operations performed between January 1, 2011 and April 1, 2013, a total of 183 consecutive surgical miscounts occurred, involving 180 patients (97 male, 83 female; median age: 55 years). Departmental protocol mandated that a radiograph of an example of the potentially retained item be taken simultaneously with each patient intraoperative radiograph. Three board-certified radiologists retrospectively reviewed these radiographs and follow-up imaging, achieving consensus on interpretation. Adherence to institutional protocol was assessed. Demographic data, surgical documentation, and clinical follow-up data were recorded.

RESULTS: The incidence of surgical miscounts was 0.9% (183 of 20,820). Only 9% (17 of 183) were resolved by discovery: outside the patient (8 cases); on intraoperative radiographs (5 cases); incidentally on follow-up radiographs (2 cases); and on retrospective review (2 cases). The false-negative rate was 44% (4 of 9). Neither of the 2 retained needles discovered postoperatively was removed. The procedures most prone to miscounts were: esophagogastrectomy (33%; 2 of 6); liver transplant (18%; 12 of 66); and Whipple procedure (16%; 7 of 44). Needles (65%) and sponges (9%) were the items that were overlooked most often. Adherence to the protocol of imaging an example of a potentially retained item was 91% (167 of 183).

CONCLUSIONS: Despite good adherence to a protocol of imaging the potentially retained items, small needles often were not visualized on intraoperative radiographs and were not subsequently removed, without known adverse events. This finding suggests that intraoperative radiography for small needles may be unnecessary, but further study is required.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app