We have located links that may give you full text access.
CASE REPORTS
JOURNAL ARTICLE
[Bullous rash around a peritoneal dialysis catheter exit site].
BACKGROUND: Cutaneous eruption around a peritoneal dialysis (PD) catheter exit site is a rare complication. Herein we report a case of bullous eruption; we discuss the diagnostic approach and the related therapeutic implications.
PATIENTS AND METHODS: A 63-year-old man presented a bullous periumbilical eruption two months after initiation of PD. Cultures of laboratory samples ruled out an infectious origin and systemic corticosteroids initiated at 0.5mg/kg for suspected eosinophilic peritonitis produced significant improvement of the cutaneous eruption. Recurrence of the bullous eruption was observed upon dose-reduction of the corticosteroid. Skin histology showed a clinical picture of eczema and direct immunofluorescence was negative. Patch testing was carried out using the European Standard Battery comprising antiseptic, cosmetic and plastic series; a semi-open test was performed with the dressing used for PD, and ROAT was carried out on the povidone iodine (Betadine™) 10% used for topical care during PD. The patch testing and ROAT were positive (++), confirming contact dermatitis due to Betadine™. The eruption totally disappeared on substitution of Betadine™ by chlorhexidine for topical antisepsis of the PD catheter, thus enabling PD to be continued rather than instituting hemodialysis.
DISCUSSION: Allergic contact dermatitis around a PD catheter is a rare and little-known complication. In the present case, ROAT testing showed sensitization to Betadine™ and enabled an alternative antisepsis solution to be found, allowing PD to be continued.
PATIENTS AND METHODS: A 63-year-old man presented a bullous periumbilical eruption two months after initiation of PD. Cultures of laboratory samples ruled out an infectious origin and systemic corticosteroids initiated at 0.5mg/kg for suspected eosinophilic peritonitis produced significant improvement of the cutaneous eruption. Recurrence of the bullous eruption was observed upon dose-reduction of the corticosteroid. Skin histology showed a clinical picture of eczema and direct immunofluorescence was negative. Patch testing was carried out using the European Standard Battery comprising antiseptic, cosmetic and plastic series; a semi-open test was performed with the dressing used for PD, and ROAT was carried out on the povidone iodine (Betadine™) 10% used for topical care during PD. The patch testing and ROAT were positive (++), confirming contact dermatitis due to Betadine™. The eruption totally disappeared on substitution of Betadine™ by chlorhexidine for topical antisepsis of the PD catheter, thus enabling PD to be continued rather than instituting hemodialysis.
DISCUSSION: Allergic contact dermatitis around a PD catheter is a rare and little-known complication. In the present case, ROAT testing showed sensitization to Betadine™ and enabled an alternative antisepsis solution to be found, allowing PD to be continued.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app