Journal Article
Research Support, Non-U.S. Gov't
Add like
Add dislike
Add to saved papers

Assisted Ventilation in Patients with Acute Respiratory Distress Syndrome: Lung-distending Pressure and Patient-Ventilator Interaction.

Anesthesiology 2015 July
BACKGROUND: In patients with acute respiratory distress syndrome (ARDS), the use of assisted mechanical ventilation is a subject of debate. Assisted ventilation has benefits over controlled ventilation, such as preserved diaphragm function and improved oxygenation. Therefore, higher level of "patient control" of ventilator assist may be preferable in ARDS. However, assisted modes may also increase the risk of high tidal volumes and lung-distending pressures. The current study aims to quantify how differences in freedom to control the ventilator affect lung-protective ventilation, breathing pattern variability, and patient-ventilator interaction.

METHODS: Twelve patients with ARDS were ventilated in a randomized order with assist pressure control ventilation (PCV), pressure support ventilation (PSV), and neurally adjusted ventilatory assist (NAVA). Transpulmonary pressure, tidal volume, diaphragm electrical activity, and patient-ventilator interaction were measured. Respiratory variability was assessed using the coefficient of variation of tidal volume.

RESULTS: During inspiration, transpulmonary pressure was slightly lower with NAVA (10.3 ± 0.7, 11.2 ± 0.7, and 9.4 ± 0.7 cm H2O for PCV, PSV, and NAVA, respectively; P < 0.01). Tidal volume was similar between modes (6.6 [5.7 to 7.0], 6.4 [5.8 to 7.0], and 6.0 [5.6 to 7.3] ml/kg for PCV, PSV, and NAVA, respectively), but respiratory variability was higher with NAVA (8.0 [6.4 to 10.0], 7.1 [5.9 to 9.0], and 17.0 [12.0 to 36.1] % for PCV, PSV, and NAVA, respectively; P < 0.001). Patient-ventilator interaction improved with NAVA (6 [5 to 8] % error) compared with PCV (29 [14 to 52] % error) and PSV (12 [9 to 27] % error); P < 0.0001.

CONCLUSION: In patients with mild-to-moderate ARDS, increasing freedom to control the ventilator maintains lung-protective ventilation in terms of tidal volume and lung-distending pressure, but it improves patient-ventilator interaction and preserves respiratory variability.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app