Clinical Study
Journal Article
Research Support, Non-U.S. Gov't
Add like
Add dislike
Add to saved papers

Estimation of creatinine clearance using plasma creatinine or cystatin C: a secondary analysis of two pharmacokinetic studies in surgical ICU patients.

BACKGROUND: In ICU patients, glomerular filtration is often impaired, but also supraphysiological values are observed ("augmented renal clearance", >130 mL/min/1.73 m(2)). Renally eliminated drugs (e.g. many antibiotics) must be adjusted accordingly, which requires a quantitative measure of renal function throughout all the range of clinically encountered values. Estimation from plasma creatinine is standard, but cystatin C may be a valuable alternative.

METHODS: This was a secondary analysis of renal function parameters in 100 ICU patients from two pharmacokinetic studies on vancomycin and betalactam antibiotics. Estimated clearance values obtained by the Cockcroft-Gault formula (eCLCG), the CKD-EPI formula (eCLCKD-EPI) or the cystatin C based Hoek formula (eCLHoek) were compared with the measured endogenous creatinine clearance (CLCR). Agreement of values was assessed by modified Bland-Altman plots and by calculating bias (median error) and precision (median absolute error). Sensitivity and specificity of estimates to identify patients with reduced (<60 mL/min/1.73 m(2)) or augmented (>130 mL/min/1.73 m(2)) CLCR were calculated.

RESULTS: The CLCR was well distributed from highly compromised to supraphysiological values (median 73.2, range 16.8-234 mL/min/1.73 m(2)), even when plasma creatinine was not elevated (≤0.8 mg/dL for women, ≤1.1 mg/dL for men). Bias and precision were +13.5 mL/min/1.73 m(2) and ±18.5 mL/min/1.73 m(2) for eCLCG, +7.59 and ±16.8 mL/min/1.73 m(2) for eCLCKD-EPI, and -4.15 and ±12.9 mL/min/1.73 m(2) for eCLHoek, respectively, with eCLHoek being more precise than the other two (p < 0.05). The central 95% of observed errors fell between -59.8 and +250 mL/min/1.73 m(2) for eCLCG, -83.9 and +79.8 mL/min/1.73 m(2) for eCLCKD-EPI, and -103 and +27.9 mL/min/1.73 m(2) for eCLHoek. Augmented renal clearance was underestimated by eCLCKD-EPI and eCLHoek. Patients with reduced CLCR were identified with good specificity by eCLCG, eCLCKD-EPI and eCLHoek (0.95, 0.97 and 0.91, respectively), but with less sensitivity (0.55, 0.55 and 0.83). For augmented renal clearance, specificity was 0.81, 0.96 and 0.96, but sensitivity only 0.69, 0.25 and 0.38.

CONCLUSIONS: Normal plasma creatinine concentrations can be highly misleading in ICU patients. Agreement of the cystatin C based eCLHoek with CLCR is better than that of the creatinine based eCLCG or eCLCKD-EPI. Detection and quantification of augmented renal clearance by estimates is problematic, and should rather rely on CLCR.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app