The efficacy and safety of epidural filter catheters when used for post-operative intra-articular anaesthesia.

Knee 2016 January
UNLABELLED: There are concerns about the risk of iatrogenic infection when employing local anaesthetic techniques with post-operative intra-articular infusions in total knee arthroplasty. This study aimed to determine the efficacy of intact epidural filters in preventing transit of bacteria and to develop a technique of administration which would prevent membrane rupture. Filter efficacy was assessed using a standardised test suspension of Pseudomonas aeruginosa. Twenty millilitres of suspension was injected through isolated epidural filters (n=10) or filters with 40cm of catheter tubing attached (n=30). For each filter, injections were carried out at 0, 8 and 24h. Filtrates were collected, incubated, sub-cultured onto Columbia horse blood agar and examined for bacterial growth. Three delivery techniques were tested: manually controlled syringe with 5ml of water at 20ml/min, forced administration syringe with 5ml of water at >240ml/min and an automated syringe driver delivering 40ml of water at 6.7ml/min. For the two techniques using syringes, three syringe sizes, 5ml, 10ml and 20ml, were tested. Each test condition was carried out on 10 filters (total n=70). Filters were examined for rupture. Intact epidural filters prevented bacterial transit in all cases. Manual controlled and automated syringe driver administration generated no filter ruptures. Manual forced administration generated 93% filter rupture. Ruptures occurred at peak pressures of approximately 620kPa. Epidural filters can be used to prevent bacterial transit. These results suggest automated devices remove the risk of filter rupture. This study is relevant to all specialties that utilise these filters during infiltration such as epidurals or other regional anaesthetic techniques.

CLINICAL RELEVANCE: This study identified that filters are prone to rupture with high infusion rates and that manual techniques are particularly vulnerable. From these results, it is recommended that pumps are used to minimise risk of filter rupture.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app