Multi-Institution Validation of an Emergency Ultrasound Image Rating Scale-A Pilot Study.
Journal of Emergency Medicine 2015 July
BACKGROUND: As bedside ultrasound (BUS) is being increasingly taught and incorporated into emergency medicine practice, measurement of BUS competency is becoming more important. The commonly adopted experiential approach to BUS competency has never been validated on a large scale, and has some limitations by design.
OBJECTIVE: Our aim was to introduce and report preliminary testing of a novel emergency BUS image rating scale (URS).
METHODS: Gallbladder BUS was selected as the test case. Twenty anonymous BUS image sets (still images and clips) were forwarded electronically to 16 reviewers (13 attendings, 3 fellows) at six training sites across the United States. Each reviewer rated the BUS sets using the pilot URS that consisted of three components, with numerical values assigned to each of the following aspects: Landmarks, Image Quality, and Annotations. Reviewers also decided whether or not each BUS set would be "Clinically Useful." Kendall τs were calculated as a measure of concordance among the reviewers.
RESULTS: Among the 13 attendings, image review experience ranged from 2-15 years, 5-300 scans per week, and averaged 7.8 years and 60 images. Kendall τs for each aspect of the URS were: Landmarks: 0.55; Image Quality: 0.57; Annotation: 0.26; Total Score: 0.63, and Clinical Usefulness: 0.45. All URS elements correlated significantly with clinical usefulness (p < 0.001). The correlation coefficient between each attending reviewer and the entire group ranged from 0.48-0.69, and was independent of image review experience beyond fellowship training.
CONCLUSION: Our novel URS had moderate-to-good inter-rater agreement in this pilot study. Based on these results, the URS will be modified for use in future investigations.
OBJECTIVE: Our aim was to introduce and report preliminary testing of a novel emergency BUS image rating scale (URS).
METHODS: Gallbladder BUS was selected as the test case. Twenty anonymous BUS image sets (still images and clips) were forwarded electronically to 16 reviewers (13 attendings, 3 fellows) at six training sites across the United States. Each reviewer rated the BUS sets using the pilot URS that consisted of three components, with numerical values assigned to each of the following aspects: Landmarks, Image Quality, and Annotations. Reviewers also decided whether or not each BUS set would be "Clinically Useful." Kendall τs were calculated as a measure of concordance among the reviewers.
RESULTS: Among the 13 attendings, image review experience ranged from 2-15 years, 5-300 scans per week, and averaged 7.8 years and 60 images. Kendall τs for each aspect of the URS were: Landmarks: 0.55; Image Quality: 0.57; Annotation: 0.26; Total Score: 0.63, and Clinical Usefulness: 0.45. All URS elements correlated significantly with clinical usefulness (p < 0.001). The correlation coefficient between each attending reviewer and the entire group ranged from 0.48-0.69, and was independent of image review experience beyond fellowship training.
CONCLUSION: Our novel URS had moderate-to-good inter-rater agreement in this pilot study. Based on these results, the URS will be modified for use in future investigations.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app