Comparative Study
Journal Article
Multicenter Study
Review
Add like
Add dislike
Add to saved papers

Detection of Spina Bifida by First Trimester Screening - Results of the Prospective Multicenter Berlin IT-Study.

Purpose  To evaluate the potential of routine assessment of intracranial translucency (IT) and other posterior brain parameters in the early detection of open spina bifida during the 11 - 14 weeks screening examination. Materials and Methods  This prospective, multicenter longitudinal study was conducted with the participation of 20 certified DEGUM II or III experts in Berlin, Germany, between June 2010 and October 2013. All pregnant women undergoing a first trimester screening were included in the study and in every patient were the IT, brain stem (BS), cisterna magna (CM), BS to occipital bone distance (BSOB) and BS/BSOB ratio measured. All patients with continuing pregnancy underwent a second trimester scan. Our data was used to develop our own reference ranges. The primary outcome parameter was the presence of open spina bifida. Results  A total of 15 526 women with 16 164 fetuses were examined. Median of the IT was 2.1 mm, of the CM 1.6 mm, of the BS 2.7 mm, of the BSOB 5.5 mm, and of the BS/BSOB ratio 0.49. There were 11 cases with open spina bifida (incidence of 6.8/10 000). The detection rate was 100 % and in all cases of spina bifida, the anomaly was detected either at the first examination (n = 8) or considered suspicious and the lesion then detected a few weeks later (n = 3). Considering individual measurements, however, the detection rate was 18 % with the complete absence of the IT and 45 % with cut-off values. For the CM measurement, the detection rate was 64 % with the absence of the CM and 73 % with cut-off values. The other parameters proved not to be predictive of open spina bifida. Conclusion  In the hands of an expert, open spina bifida can be reliably diagnosed early in gestation during the 11 - 14 weeks screening. The measurement of different parameters of the posterior brain, especially the CM and the use of cut-off values are of tremendous benefit in achieving a high sensitivity in the detection rate.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app