We have located links that may give you full text access.
Novel Use of Glidescope Indirect Laryngoscopy for Insertion of a Minnesota Tube for Variceal Bleeding.
Journal of Emergency Medicine 2015 July
BACKGROUND: With improvements in endoscopic and interventional radiologic therapies, insertion of gastroesophageal balloon tamponade catheters, commonly known as Sengstaken-Blakemore or Minnesota tubes, is a rarely performed procedure for esophageal or gastric variceal bleeding. In small hospitals or freestanding emergency departments, endoscopic or interventional radiology (IR) therapies might not be available, so patients with exsanguinating variceal bleeding must be stabilized or temporized for transport to larger hospitals. Occasionally, tamponade devices are necessary as a rescue therapy for failed endoscopic or IR therapies or can be used as definitive therapy in select cases. In addition to being rarely performed, there are multiple technical complications associated with blind insertion of tamponade catheters.
DISCUSSION: We describe a novel use of indirect laryngoscopy using a Glidescope for assisting in placement of a Minnesota tube in 4 patients with exsanguinating esophageal bleeding.
CONCLUSIONS: Insertion of a Minnesota tube for bleeding esophageal or gastric varices is an uncommon, technically challenging procedure that can be lifesaving, and is something emergency physicians, intensivists, and gastroenterologists should be capable of performing. Addition of indirect laryngoscopy may help to improve rapid, safe, and successful placement of these devices.
DISCUSSION: We describe a novel use of indirect laryngoscopy using a Glidescope for assisting in placement of a Minnesota tube in 4 patients with exsanguinating esophageal bleeding.
CONCLUSIONS: Insertion of a Minnesota tube for bleeding esophageal or gastric varices is an uncommon, technically challenging procedure that can be lifesaving, and is something emergency physicians, intensivists, and gastroenterologists should be capable of performing. Addition of indirect laryngoscopy may help to improve rapid, safe, and successful placement of these devices.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app