We have located links that may give you full text access.
JOURNAL ARTICLE
MULTICENTER STUDY
OBSERVATIONAL STUDY
Diagnostic accuracy of placental growth factor and ultrasound parameters to predict the small-for-gestational-age infant in women presenting with reduced symphysis-fundus height.
Ultrasound in Obstetrics & Gynecology 2015 August
OBJECTIVES: To assess the diagnostic accuracy of placental growth factor (PlGF) and ultrasound parameters to predict delivery of a small-for-gestational-age (SGA) infant in women presenting with reduced symphysis-fundus height (SFH).
METHODS: This was a multicenter prospective observational study recruiting 601 women with a singleton pregnancy and reduced SFH between 24 and 37 weeks' gestation across 11 sites in the UK and Canada. Plasma PlGF concentration < 5(th) centile, estimated fetal weight (EFW) < 10(th) centile, umbilical artery Doppler pulsatility index > 95(th) centile and oligohydramnios (amniotic fluid index < 5 cm) were compared as predictors for a SGA infant < 3(rd) customized birth-weight centile and adverse perinatal outcome. Test performance statistics were calculated for all parameters in isolation and in combination.
RESULTS: Of the 601 women recruited, 592 were analyzed. For predicting delivery of SGA < 3(rd) centile (n = 78), EFW < 10(th) centile had 58% sensitivity (95% CI, 46-69%) and 93% negative predictive value (NPV) (95% CI, 90-95%), PlGF had 37% sensitivity (95% CI, 27-49%) and 90% NPV (95% CI, 87-93%); in combination, PlGF and EFW < 10(th) centile had 69% sensitivity (95% CI, 55-81%) and 93% NPV (95% CI, 89-96%). The equivalent receiver-operating characteristics (ROC) curve areas were 0.79 (95% CI, 0.74-0.84) for EFW < 10(th) centile, 0.70 (95% CI, 0.63-0.77) for low PlGF and 0.82 (95% CI, 0.77-0.86) in combination.
CONCLUSIONS: For women presenting with reduced SFH, ultrasound parameters had modest test performance for predicting delivery of SGA < 3(rd) centile. PlGF performed no better than EFW < 10(th) centile in determining delivery of a SGA infant.
METHODS: This was a multicenter prospective observational study recruiting 601 women with a singleton pregnancy and reduced SFH between 24 and 37 weeks' gestation across 11 sites in the UK and Canada. Plasma PlGF concentration < 5(th) centile, estimated fetal weight (EFW) < 10(th) centile, umbilical artery Doppler pulsatility index > 95(th) centile and oligohydramnios (amniotic fluid index < 5 cm) were compared as predictors for a SGA infant < 3(rd) customized birth-weight centile and adverse perinatal outcome. Test performance statistics were calculated for all parameters in isolation and in combination.
RESULTS: Of the 601 women recruited, 592 were analyzed. For predicting delivery of SGA < 3(rd) centile (n = 78), EFW < 10(th) centile had 58% sensitivity (95% CI, 46-69%) and 93% negative predictive value (NPV) (95% CI, 90-95%), PlGF had 37% sensitivity (95% CI, 27-49%) and 90% NPV (95% CI, 87-93%); in combination, PlGF and EFW < 10(th) centile had 69% sensitivity (95% CI, 55-81%) and 93% NPV (95% CI, 89-96%). The equivalent receiver-operating characteristics (ROC) curve areas were 0.79 (95% CI, 0.74-0.84) for EFW < 10(th) centile, 0.70 (95% CI, 0.63-0.77) for low PlGF and 0.82 (95% CI, 0.77-0.86) in combination.
CONCLUSIONS: For women presenting with reduced SFH, ultrasound parameters had modest test performance for predicting delivery of SGA < 3(rd) centile. PlGF performed no better than EFW < 10(th) centile in determining delivery of a SGA infant.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app