Evaluation of routine postoperative chest roentgenogram for determination of the correct position of permanent central venous catheters tip.
Journal of Research in Medical Sciences : the Official Journal of Isfahan University of Medical Sciences 2015 January
BACKGROUND: Proper placement of central venous catheter (CVC) tip could reduce early and late catheter-related complications. Although the live fluoroscopy is standard of care for placement of the catheter, it is not available in many centers. Therefore, the present study evaluated the sensitivity and specificity of bedside chest X-ray (CXR) for proper positioning of the catheter tip.
MATERIALS AND METHODS: A total of 82 adult patients undergoing elective placement of tunneled CVC were enrolled in this study during 2010-2012. The catheter tip position was evaluated by postoperative bedside chest radiographs as well as trans-thoracic echocardiogram as definite diagnostic tool. The catheter position was considered correct if the tip was positioned in the right atrium both in CXR or echocardiography. Finally, CXRs interpreted by expert radiologist. Thus findings were compared by echocardiography. Sensitivity, specificity, accuracy, positive, and negative predictive values were calculated. Data were analyzed using SPSS version 16 (SPSS Inc., Chicago, IL), and P < 0.05 considered as significant.
RESULTS: The patients were 57.37 ± 18.91 years of age, weighed 65.79 ± 15.58 kg and were 166.36 ± 9.91 cm tall. Sensitivity and specificity of CXR for proper catheter tip position were 74.3% and 58.3%, respectively. Positive and negative predictive values were 91.2% and 28%. In addition accuracy, positive likelihood ratio, and negative likelihood ratio were 71.9%, 1.78, and 2.27 respectively.
CONCLUSION: Bedside CXR alone does not reliably predict malpositioning after CVC placement.
MATERIALS AND METHODS: A total of 82 adult patients undergoing elective placement of tunneled CVC were enrolled in this study during 2010-2012. The catheter tip position was evaluated by postoperative bedside chest radiographs as well as trans-thoracic echocardiogram as definite diagnostic tool. The catheter position was considered correct if the tip was positioned in the right atrium both in CXR or echocardiography. Finally, CXRs interpreted by expert radiologist. Thus findings were compared by echocardiography. Sensitivity, specificity, accuracy, positive, and negative predictive values were calculated. Data were analyzed using SPSS version 16 (SPSS Inc., Chicago, IL), and P < 0.05 considered as significant.
RESULTS: The patients were 57.37 ± 18.91 years of age, weighed 65.79 ± 15.58 kg and were 166.36 ± 9.91 cm tall. Sensitivity and specificity of CXR for proper catheter tip position were 74.3% and 58.3%, respectively. Positive and negative predictive values were 91.2% and 28%. In addition accuracy, positive likelihood ratio, and negative likelihood ratio were 71.9%, 1.78, and 2.27 respectively.
CONCLUSION: Bedside CXR alone does not reliably predict malpositioning after CVC placement.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app