A new method of locating foramen rotundum and its anatomic study.
Journal of Craniofacial Surgery 2015 March
PURPOSE: The purpose of this study is to provide a new method to locate the foramen rotundum (FR) based on the structures in the wall of sphenoid.
MATERIALS AND METHODS: Computed tomographic angiography images of 172 FR in adults and 10 bony specimens were reviewed. The measurement was on coronal, sagittal, and axial planes after multiplanar reconstruction. The diameter, length, and direction of FR were measured. The middle lowest point of sellar region, the sagittal midline, and the bottom of sphenoid sinus were selected as the landmarks to locate the FR.
RESULT: The FR can be found and identified easily on computed tomographic angiography image. The bony diameter measured in CT image is in accordance with that in specimen. The anterior opening and posterior opening can be located by the stationary structures in the sphenoid sinus.
CONCLUSIONS: The FR is a stationary bony structure; its length, diameter, and angle are relatively constant; and it can be easily located by the data measured in this study. The FR should be protected in the process of transsphenoid approach as well as be precisely located by the procedure about it.
MATERIALS AND METHODS: Computed tomographic angiography images of 172 FR in adults and 10 bony specimens were reviewed. The measurement was on coronal, sagittal, and axial planes after multiplanar reconstruction. The diameter, length, and direction of FR were measured. The middle lowest point of sellar region, the sagittal midline, and the bottom of sphenoid sinus were selected as the landmarks to locate the FR.
RESULT: The FR can be found and identified easily on computed tomographic angiography image. The bony diameter measured in CT image is in accordance with that in specimen. The anterior opening and posterior opening can be located by the stationary structures in the sphenoid sinus.
CONCLUSIONS: The FR is a stationary bony structure; its length, diameter, and angle are relatively constant; and it can be easily located by the data measured in this study. The FR should be protected in the process of transsphenoid approach as well as be precisely located by the procedure about it.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app