Fluoroscopic evaluation of contrast distribution within the adductor canal.
Regional Anesthesia and Pain Medicine 2015 March
BACKGROUND AND OBJECTIVES: This case series assesses the in vivo spread of contrast within the adductor canal in subjects who recently underwent a total knee arthroplasty. A previous analysis of profound leg weakness with a continuous adductor canal revealed contrast spread from the adductor canal to the femoral triangle with as little as 2 mL of volume.
METHODS: We enrolled 10 American Society of Anesthesiologists class II-III subjects. Maximum voluntary isometric contraction was measured to assess quadriceps strength before and after surgery. Contrast was then injected continuously via electronic pump into the adductor canal, and fluoroscopy was used to capture images after 1-mL increments. For analysis, the femur was divided into 8 equidistant sectors between the lesser trochanter and medial epicondyle.
RESULTS: Contrast did not reach the level of the lesser trochanter or the medial epicondyle of the femur in any subject. The greatest spread after 5 mL of contrast was 4 sectors. Sixty percent of subjects had contrast spread within either the same sector as the catheter tip or 1 sector distally. No subjects demonstrated additional proximal spread of contrast after 4 mL.
CONCLUSIONS: This study reveals that in vivo continuous infusions within the adductor canal spread in both a cephalad and caudad direction in limited fashion. Although a previous report described proximal spread of injectate to the level of the common femoral nerve, this event is infrequent.
METHODS: We enrolled 10 American Society of Anesthesiologists class II-III subjects. Maximum voluntary isometric contraction was measured to assess quadriceps strength before and after surgery. Contrast was then injected continuously via electronic pump into the adductor canal, and fluoroscopy was used to capture images after 1-mL increments. For analysis, the femur was divided into 8 equidistant sectors between the lesser trochanter and medial epicondyle.
RESULTS: Contrast did not reach the level of the lesser trochanter or the medial epicondyle of the femur in any subject. The greatest spread after 5 mL of contrast was 4 sectors. Sixty percent of subjects had contrast spread within either the same sector as the catheter tip or 1 sector distally. No subjects demonstrated additional proximal spread of contrast after 4 mL.
CONCLUSIONS: This study reveals that in vivo continuous infusions within the adductor canal spread in both a cephalad and caudad direction in limited fashion. Although a previous report described proximal spread of injectate to the level of the common femoral nerve, this event is infrequent.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app