Add like
Add dislike
Add to saved papers

Geometry and respiratory-induced deformation of abdominal branch vessels and stents after complex endovascular aneurysm repair.

OBJECTIVE: This study quantified the geometry and respiration-induced deformation of abdominal branch vessels and stents after fenestrated (F-) and snorkel (Sn-) endovascular aneurysm repair (EVAR).

METHODS: Twenty patients (80% male; mean age, 75.2 ± 7.4 years; mean aneurysm diameter, 6.2 ± 1.8 cm) underwent computed tomography angiography during inspiratory and expiratory breath hold protocols after F-EVAR (n = 11) or Sn-EVAR (n = 9). Centerlines for the aorta and visceral vessels were extracted from three-dimensional models. Branch angles were computed relative to the orthogonal plane at the branch ostia, and end-stent angles of the left renal artery (LRA) and right renal artery (RRA) were computed relative to the distal stent orientation. The radius of peak curvature was defined by the circumscribed circle at the highest curvature.

RESULTS: Sn-renal branches were more downward-angled than F-renal branches (P < .04). At the distal ends of the RRA stents, Sn-RRAs were angled greater than F-RRAs (P < .03) and had a smaller radius of peak curvature (P < .03). With expiration, the end-stent angle of Sn-LRAs increased by 4° ± 4° (P < .02) and exhibited a significant reduction of radius of curvature (P < .04). The unstented celiac arteries were more downward-angled (P < .02, inspiration), with a smaller radius of curvature (P < .00001), than the unstented superior mesenteric arteries. With expiration, the celiac arteries angled upwards by 9° ± 9° (P < .0005), which was greater than the superior mesenteric arteries (P < .03). At a median postoperative follow-up of 12.6 months (range, 1.0-37.1 months), branch vessel patency was 100%, serum creatinine levels remained stable, and one reintervention was required for a type III endoleak at the main body-LRA stent interface.

CONCLUSIONS: Sn-renals were angled more inferiorly at the branch and more angulated at the stent end than F-renals due to stent placement strategies. Sn-LRAs exhibited a significant change in end-stent angle and curvature during respiration, a finding that may compromise long-term durability for parallel stent graft configurations. Further investigation is warranted to better optimize anatomic, patient, and branch vessel stent selection between fenestrated and snorkel strategies and their relationship to long-term patency.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app