Safety and Effectiveness of UFE in Fibroids Larger than 10 cm.
Cardiovascular and Interventional Radiology 2015 October
INTRODUCTION: Early literature suggested that the size of the uterus, the size of the dominant fibroid, and the amount of applied embolization particles would be the risk factors for major postprocedural complications, but recent publications have confuted these early results. The purpose of our study was to evaluate whether the size of the dominant fibroid would influence the complication rate and effectiveness in a large single-center cohort.
PATIENTS AND METHODS: From 28 April 2008 until 31 December 2012, 303 patients had uterine artery embolization (UAE). 262 patients had small [largest diameter <10 cm (Group 1)], 41 patients had large [largest diameter >10 cm (Group 2)] fibroid. UAE was performed from unilateral femoral access using 500-710 and 355-500 µm polyvinyl alcohol particles. Periprocedural and postprocedural complications and numerical analog quality-of-life scores (0-unbearable symptoms; 100-perfect quality of life) were listed and statistically analyzed.
RESULTS: During the mean follow-up time [7.79 ± 5.16 (SD) month], data on 275 patients (275/303 = 90.8 %) were available. Quality-of-life score was 33.3 ± 23.5 and 33.5 ± 24.1 before, whereas 85.6 ± 16.0 and 81.5 ± 23.5 after UAE in Group 1 and Group 2, respectively, (Mann-Whitney U test one-sided, p = 0.365). There were 4 myoma expulsions, 1 acute myomectomy, and 2 acute hysterectomies reported from Group 1, meanwhile 1 myoma expulsion, 1 acute myomectomy, and 2 acute hysterectomies were documented from Group 2 (NS differences).
CONCLUSION: There was no significant difference in the effectiveness and in the number of minor and major complications between fibroids with <10 cm largest diameter compared to those >10 cm.
PATIENTS AND METHODS: From 28 April 2008 until 31 December 2012, 303 patients had uterine artery embolization (UAE). 262 patients had small [largest diameter <10 cm (Group 1)], 41 patients had large [largest diameter >10 cm (Group 2)] fibroid. UAE was performed from unilateral femoral access using 500-710 and 355-500 µm polyvinyl alcohol particles. Periprocedural and postprocedural complications and numerical analog quality-of-life scores (0-unbearable symptoms; 100-perfect quality of life) were listed and statistically analyzed.
RESULTS: During the mean follow-up time [7.79 ± 5.16 (SD) month], data on 275 patients (275/303 = 90.8 %) were available. Quality-of-life score was 33.3 ± 23.5 and 33.5 ± 24.1 before, whereas 85.6 ± 16.0 and 81.5 ± 23.5 after UAE in Group 1 and Group 2, respectively, (Mann-Whitney U test one-sided, p = 0.365). There were 4 myoma expulsions, 1 acute myomectomy, and 2 acute hysterectomies reported from Group 1, meanwhile 1 myoma expulsion, 1 acute myomectomy, and 2 acute hysterectomies were documented from Group 2 (NS differences).
CONCLUSION: There was no significant difference in the effectiveness and in the number of minor and major complications between fibroids with <10 cm largest diameter compared to those >10 cm.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app