Removing a misplaced retropubic midurethral sling from the urethra and bladder neck using ear, nose, and throat instruments.

BACKGROUND: The retropubic tension-free vaginal tape (TVT) procedure is a common procedure with complications attributed to voiding dysfunction, bladder perforation, and bleeding. We present a case of successful removal of a retropubic midurethral sling from the urethra using a head lamp and a combination of ear, nose, and throat instruments.

CASE: A 63-year-old woman presented to our clinic with the symptom of gross hematuria after having undergone a TVT procedure. On office cystoscopy, the sling was noted to be placed within the urethral mucosa. Removal of the mesh was performed using a nasal speculum, left and right ethmoid scissors, left and right Blakesley graspers, and a head lamp to dissect the mesh directly out of the urethra.

CONCLUSION: The utilization of ear, nose, and throat tools allowed us to resect the intraurethral mesh without necessitating incision of the urethral sphincter.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app