PURPOSE: Minimal invasion computer-assisted neurosurgical procedures with various tool insertions into the brain may carry hemorrhagic risks and neurological deficits. The goal of this study is to investigate the role of computer-based surgical trajectory planning tools in improving the potential safety of image-based stereotactic neurosurgery.

METHODS: Multi-sequence MRI studies of eight patients who underwent image-guided neurosurgery were retrospectively processed to extract anatomical structures-head surface, ventricles, blood vessels, white matter fibers tractography, and fMRI data of motor, sensory, speech, and visual areas. An experienced neurosurgeon selected one target for each patient. Five neurosurgeons planned a surgical trajectory for each patient using three planning methods: (1) conventional; (2) visualization, in which scans are augmented with overlays of anatomical structures and functional areas; and (3) automatic, in which three surgical trajectories with the lowest expected risk score are automatically computed. For each surgeon, target, and method, we recorded the entry point and its surgical trajectory and computed its expected risk score and its minimum distance from the key structures.

RESULTS: A total of 120 surgical trajectories were collected (5 surgeons, 8 targets, 3 methods). The surgical trajectories expected risk scores improved by 76% ([Formula: see text], two-sample student's t test); the average distance of a trajectory from nearby blood vessels increased by 1.6 mm ([Formula: see text]) from 0.6 to 2.2 mm (243%). The initial surgical trajectories were changed in 85% of the cases based on the expected risk score and the trajectory distance from blood vessels.

CONCLUSIONS: Computer-based patient-specific preoperative planning of surgical trajectories that minimize the expected risk of vascular and neurological damage due to incorrect tool placement is a promising technique that yields consistent improvements.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app