The use of continuous glucose monitoring systems in a pediatric population with type 1 diabetes mellitus in real-life settings: the AWeSoMe Study Group experience.
Acta Diabetologica 2015 April
AIMS: The aim of the study was (a) to compare annual glycemic control in pediatric patients with type 1 diabetes mellitus (T1DM) who used a healthcare-funded continuous glucose monitoring system (RT-CGMS) to that of those who performed self-monitoring blood glucose (SMBG) only, in a real-life setting, and (b) to define parameters associated with compliance and glycemic control.
METHODS: A total of 149 youth with T1DM (52.3 % females), mean age 11.8 ± 3.6 years, and 83 in the CGMS group were followed prospectively for 12 months. Glycemic control parameters and compliance to RT-CGMS were assessed periodically.
RESULTS: Glycemic parameters did not differ significantly between the groups during follow-up periods. The time spent with RT-CGMS decreased and only 38 % used it for more than 75 % of the time during the 12 months (consistent users). Mean HbA1c decreased by 0.27 % in consistent users and increased by 0.21 % among intermittent users (used RT-CGMS less than 75 % of time), p = 0.013. Consistent users were younger 10. 6 ± 4.2 vs. 12.5 ± 3.6, p = 0.07, and had higher frequency of SMBG at baseline, 10.6 ± 4.9 vs. 6.3 ± 2.8, p = 0.011.
CONCLUSIONS: The adoption of RT-CGMS was low, even in a healthcare system that funds its use. Caregivers should consider patient characteristics when recommending RT-CGMS use.
METHODS: A total of 149 youth with T1DM (52.3 % females), mean age 11.8 ± 3.6 years, and 83 in the CGMS group were followed prospectively for 12 months. Glycemic control parameters and compliance to RT-CGMS were assessed periodically.
RESULTS: Glycemic parameters did not differ significantly between the groups during follow-up periods. The time spent with RT-CGMS decreased and only 38 % used it for more than 75 % of the time during the 12 months (consistent users). Mean HbA1c decreased by 0.27 % in consistent users and increased by 0.21 % among intermittent users (used RT-CGMS less than 75 % of time), p = 0.013. Consistent users were younger 10. 6 ± 4.2 vs. 12.5 ± 3.6, p = 0.07, and had higher frequency of SMBG at baseline, 10.6 ± 4.9 vs. 6.3 ± 2.8, p = 0.011.
CONCLUSIONS: The adoption of RT-CGMS was low, even in a healthcare system that funds its use. Caregivers should consider patient characteristics when recommending RT-CGMS use.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app