Biomechanical analysis of augmented plate fixation for the treatment of vertical shear femoral neck fractures.
Journal of Orthopaedic Trauma 2015 March
OBJECTIVES: To compare the strength of augmented versus nonaugmented fixation techniques for stabilizing vertical shear femoral neck fractures.
METHODS: Two surgical screw constructs were tested with and without augmentation using 40 composite femurs: (1) 7.3-mm cannulated screws placed in an inverted triangular configuration and (2) 135-degree dynamic hip screw (DHS). The augmentation consisted of a 2.7-mm locking plate placed on the anterior-inferior femoral neck. Specimens in all 4 groups were tested with load to failure, while failure loads, energy absorbed to failure, and axial stiffness were determined. These data were then analyzed using a two-way (construct × augmentation) analysis of variance.
RESULTS: There was no statistically significant interaction between screw construct and augmentation for load to failure (P = 0.11). Augmentation with the 2.7-mm locking plate increased failure loads in both constructs on average by 83% (2409 vs. 4417 N, P < 0.01). Femurs instrumented with cannulated screws had 26% higher loads to failure than those instrumented with DHS (3879 vs. 3087 N, P < 0.01). On average, the augmentation increased energy absorbed to failure by 183% and constructs' stiffness by 35%.
CONCLUSIONS: The strength of surgical repairs of the vertical shear femoral neck fractures can be significantly augmented with the 2.7-mm locking plate. The construct with the cannulated screws was significantly stronger than the DHS construct.
METHODS: Two surgical screw constructs were tested with and without augmentation using 40 composite femurs: (1) 7.3-mm cannulated screws placed in an inverted triangular configuration and (2) 135-degree dynamic hip screw (DHS). The augmentation consisted of a 2.7-mm locking plate placed on the anterior-inferior femoral neck. Specimens in all 4 groups were tested with load to failure, while failure loads, energy absorbed to failure, and axial stiffness were determined. These data were then analyzed using a two-way (construct × augmentation) analysis of variance.
RESULTS: There was no statistically significant interaction between screw construct and augmentation for load to failure (P = 0.11). Augmentation with the 2.7-mm locking plate increased failure loads in both constructs on average by 83% (2409 vs. 4417 N, P < 0.01). Femurs instrumented with cannulated screws had 26% higher loads to failure than those instrumented with DHS (3879 vs. 3087 N, P < 0.01). On average, the augmentation increased energy absorbed to failure by 183% and constructs' stiffness by 35%.
CONCLUSIONS: The strength of surgical repairs of the vertical shear femoral neck fractures can be significantly augmented with the 2.7-mm locking plate. The construct with the cannulated screws was significantly stronger than the DHS construct.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app