We have located links that may give you full text access.
Meconium-stained amniotic fluid--risk factors and immediate perinatal outcomes among SGA infants.
OBJECTIVE: To detect factors that are associated with meconium-stained amniotic fluid (MSAF) among deliveries of small for gestational age (SGA) neonates and to identify perinatal outcomes of deliveries of SGA infants complicated with MSAF.
METHODS: A population-based study comparing deliveries of SGA neonates with and without MSAF was conducted. Deliveries occurred during the years 1988-2007 at the Soroka University Medical Center. Risk factors for MSAF among SGA infants were evaluated. Incidence of adverse pregnancy outcomes were compared between deliveries of SGA neonates with and without MSAF.
RESULTS: During the study period 9583 deliveries were of SGA neonates. Of these, 16.6% (n = 1597) were complicated with MSAF. Among SGA neonates, older maternal age, multiparty, lack of prenatal care and weight were significantly associated with MSAF. Having delivered an SGA infant with MSAF was associated with decreased rates of induction of labor and increased rates of labor dystocia, delivery by cesarean section and fetal distress. Using multivariable regression models, having delivered an SGA infant with MSAF was independently associated with fetal distress.
CONCLUSION: Among SGA neonates, deliveries complicated with MSAF are associated with additional adverse pregnancy outcomes.
METHODS: A population-based study comparing deliveries of SGA neonates with and without MSAF was conducted. Deliveries occurred during the years 1988-2007 at the Soroka University Medical Center. Risk factors for MSAF among SGA infants were evaluated. Incidence of adverse pregnancy outcomes were compared between deliveries of SGA neonates with and without MSAF.
RESULTS: During the study period 9583 deliveries were of SGA neonates. Of these, 16.6% (n = 1597) were complicated with MSAF. Among SGA neonates, older maternal age, multiparty, lack of prenatal care and weight were significantly associated with MSAF. Having delivered an SGA infant with MSAF was associated with decreased rates of induction of labor and increased rates of labor dystocia, delivery by cesarean section and fetal distress. Using multivariable regression models, having delivered an SGA infant with MSAF was independently associated with fetal distress.
CONCLUSION: Among SGA neonates, deliveries complicated with MSAF are associated with additional adverse pregnancy outcomes.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app