We have located links that may give you full text access.
JOURNAL ARTICLE
MULTICENTER STUDY
Combined use of aortic dissection detection risk score and D-dimer in the diagnostic workup of suspected acute aortic dissection.
International Journal of Cardiology 2014 July 16
BACKGROUND: Acute aortic dissection (AD) represents a diagnostic conundrum. Validated algorithms are particularly needed to identify patients where AD could be ruled out without aortic imaging. We evaluated the diagnostic accuracy of a strategy combining the aortic dissection detection (ADD) risk score with D-dimer, a sensitive biomarker of AD.
METHODS: Patients from two clinical centers with suspected AD were prospectively enrolled in a registry, from January 2008 to March 2013. The ADD risk score was calculated by retrospective blinded chart review. For D-dimer, a cutoff of 500 ng/ml was applied.
RESULTS: AD was diagnosed in 233 of 1035 (22.5%) patients. The ADD risk score was 0 in 322 (31.1%), 1 in 508 (49.1%) and >1 in 205 (19.8%) patients. The sensitivity and the failure rate of D-dimer were 100% and 0% in patients with ADD score 0, versus 97.5% (95% CI 91.4-99.6%) and 4.2% (95% CI 0.7-12.5%) in patients with ADD risk score >1. In patients with ADD risk score ≤ 1, the sensitivity and the failure rate of D-dimer were 98.7% (95% CI 95.3-99.8%) and 0.8% (95% CI 0.1-2.6%). The diagnostic efficiency of D-dimer in patients with ADD risk score 0 and ≤ 1 was 8.9% (95% CI 7.2-10.7%) and 23.6% (95% CI 21.1-26.2%) respectively.
CONCLUSIONS: In a large cohort of patients with suspected AD, the presence of ADD risk score 0 or ≤ 1 combined with a negative D-dimer accurately and efficiently ruled out AD.
METHODS: Patients from two clinical centers with suspected AD were prospectively enrolled in a registry, from January 2008 to March 2013. The ADD risk score was calculated by retrospective blinded chart review. For D-dimer, a cutoff of 500 ng/ml was applied.
RESULTS: AD was diagnosed in 233 of 1035 (22.5%) patients. The ADD risk score was 0 in 322 (31.1%), 1 in 508 (49.1%) and >1 in 205 (19.8%) patients. The sensitivity and the failure rate of D-dimer were 100% and 0% in patients with ADD score 0, versus 97.5% (95% CI 91.4-99.6%) and 4.2% (95% CI 0.7-12.5%) in patients with ADD risk score >1. In patients with ADD risk score ≤ 1, the sensitivity and the failure rate of D-dimer were 98.7% (95% CI 95.3-99.8%) and 0.8% (95% CI 0.1-2.6%). The diagnostic efficiency of D-dimer in patients with ADD risk score 0 and ≤ 1 was 8.9% (95% CI 7.2-10.7%) and 23.6% (95% CI 21.1-26.2%) respectively.
CONCLUSIONS: In a large cohort of patients with suspected AD, the presence of ADD risk score 0 or ≤ 1 combined with a negative D-dimer accurately and efficiently ruled out AD.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app