We have located links that may give you full text access.
EVALUATION STUDIES
JOURNAL ARTICLE
MULTICENTER STUDY
Is the 12-lead electrocardiogram during antidromic circus movement tachycardia helpful in predicting the ablation site in atriofascicular pathways?
AIMS: Unlike in the Wolff-Parkinson-White syndrome, there has been no systematic study on the role of the pre-excitation pattern in predicting the ablation site in patients with atriofascicular (AF) pathways. We assessed in a large cohort the value of the 12-lead electrocardiogram (ECG) during antidromic tachycardia (ADT) to predict the site of ablation.
METHODS AND RESULTS: Forty-five patients were studied, 23 males (51%), mean age of 27 ± 12 years with 46 AF pathways and 48 ADT using the AF pathway for A-V conduction. Inclusion required induction of a sustained ADT and successful ablation. Ablation site was assessed during LAO 45° projection and clockwise classified as hours in posteroseptal, posterolateral, lateral, anterolateral, and anteroseptal tricuspid annulus as follows: 05:00-07:00, >07:00-08:00, >08:00-09:00, >09:00-11:00, and >11:00-13:00 o'clock. The QRS axis was assessed during ADT and classified as normal (>+15°), horizontal (+15° to -30°), and superior (<-30°). During ADT axis was superior (-57° ± 10°) in 15 (31%), horizontal (-11° ± 14°) in 22 (46%), and normal (+45° ± 16°) in 11 (23%) patients. The correct ablation site did not differ between the different groups of QRS axis. QRS width during ADT was narrower in patients with a normal when compared with a horizontal and leftward axis (127 ± 14 vs. 145 ± 12 ms, P < 0.0001), and the V-H interval was shorter (4 ± 3 ms vs. 19 ± 22 ms, P = 0.03).
CONCLUSIONS: There was no correlation between the AF pathway ablation site and the QRS axis during ADT. The 12-lead ECG during maximal pre-excitation does not predict the proper site of tricuspid annulus ablation in patients with A-V conduction over an AF pathway.
METHODS AND RESULTS: Forty-five patients were studied, 23 males (51%), mean age of 27 ± 12 years with 46 AF pathways and 48 ADT using the AF pathway for A-V conduction. Inclusion required induction of a sustained ADT and successful ablation. Ablation site was assessed during LAO 45° projection and clockwise classified as hours in posteroseptal, posterolateral, lateral, anterolateral, and anteroseptal tricuspid annulus as follows: 05:00-07:00, >07:00-08:00, >08:00-09:00, >09:00-11:00, and >11:00-13:00 o'clock. The QRS axis was assessed during ADT and classified as normal (>+15°), horizontal (+15° to -30°), and superior (<-30°). During ADT axis was superior (-57° ± 10°) in 15 (31%), horizontal (-11° ± 14°) in 22 (46%), and normal (+45° ± 16°) in 11 (23%) patients. The correct ablation site did not differ between the different groups of QRS axis. QRS width during ADT was narrower in patients with a normal when compared with a horizontal and leftward axis (127 ± 14 vs. 145 ± 12 ms, P < 0.0001), and the V-H interval was shorter (4 ± 3 ms vs. 19 ± 22 ms, P = 0.03).
CONCLUSIONS: There was no correlation between the AF pathway ablation site and the QRS axis during ADT. The 12-lead ECG during maximal pre-excitation does not predict the proper site of tricuspid annulus ablation in patients with A-V conduction over an AF pathway.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app