Airway management and endoscopic treatment of subglottic and tracheal stenosis: the laryngeal mask airway technique.
OBJECTIVES: The objective is to present clinical outcomes of subglottic and tracheal stenosis treated by flexible bronchoscopic delivery of carbon dioxide (CO2) laser via laryngeal mask airway (LMA).
METHODS: All consecutive, nontracheotomy dependent cases of subglottic and tracheal stenosis treated endoscopically over a 4-year period were retrospectively reviewed. The surgical approach consisted of radial incisions using a flexible fiber-based CO2 laser, balloon dilation, and topical application of mitomycin C. Ventilation during the procedure occurred through the LMA, and the CO2 laser fiber was delivered through the working channel of a flexible bronchoscope passed through the LMA. Number of dilations, period between dilations, and operative times were reviewed.
RESULTS: Eleven patients who underwent airway intervention during the study period were identified. Average follow-up was 28 months. Etiologies of airway stenosis included intubation injury (6), idiopathic (4), or autoimmune disease (1), requiring an average of 1.3, 1.5, and 3 dilations, respectively. Average operative time was 67 minutes. Autoimmune etiology correlated with more frequent dilations.
CONCLUSION: LMA is an effective way to manage ventilation while simultaneously allowing unencumbered flexible bronchoscopic access for laser surgery, balloon dilation, and mitomycin C application for airway stenosis. Long-term success in treating stenosis is achievable using this technique.
METHODS: All consecutive, nontracheotomy dependent cases of subglottic and tracheal stenosis treated endoscopically over a 4-year period were retrospectively reviewed. The surgical approach consisted of radial incisions using a flexible fiber-based CO2 laser, balloon dilation, and topical application of mitomycin C. Ventilation during the procedure occurred through the LMA, and the CO2 laser fiber was delivered through the working channel of a flexible bronchoscope passed through the LMA. Number of dilations, period between dilations, and operative times were reviewed.
RESULTS: Eleven patients who underwent airway intervention during the study period were identified. Average follow-up was 28 months. Etiologies of airway stenosis included intubation injury (6), idiopathic (4), or autoimmune disease (1), requiring an average of 1.3, 1.5, and 3 dilations, respectively. Average operative time was 67 minutes. Autoimmune etiology correlated with more frequent dilations.
CONCLUSION: LMA is an effective way to manage ventilation while simultaneously allowing unencumbered flexible bronchoscopic access for laser surgery, balloon dilation, and mitomycin C application for airway stenosis. Long-term success in treating stenosis is achievable using this technique.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app