Ultrasound molecular imaging of transient acute myocardial ischemia with a clinically translatable P- and E-selectin targeted contrast agent: correlation with the expression of selectins.
Investigative Radiology 2014 April
OBJECTIVE: The diagnosis of acute coronary syndrome remains challenging especially in patients without clear symptoms or electrocardiographic and/or biomarker features. A hallmark of ischemia/reperfusion is activation of endothelial cells leading to altered expression of molecular markers, including selectins. In this context, we aimed to validate the value of ultrasound molecular imaging for detecting transient myocardial ischemia by using a clinically translatable dual P- and E-selectin-targeted ultrasound contrast agent (UCA) and microbubble (MB(selectin)).
MATERIAL AND METHODS: Transient (20 minutes) myocardial ischemia of rat heart was produced by ligation of the left anterior descending coronary artery ligation followed by 2-, 5-, or 24-hour reperfusion. Imaging of the transient ischemic event was achieved by the use of MB(selectin). Performance of this clinically translatable targeted UCA was compared with that of antibody-targeted streptavidin MBs. Finally, immunohistochemistry staining of rat myocardial ischemic tissue was performed to assess expression of selectins accessible to targeted UCA.
RESULTS: In rats subjected to myocardial ischemia (20 minutes) followed by reperfusion (2 hours), injection of MB(selectin) produced high late phase (ie, 10-minute postinjection) ultrasound molecular imaging enhancement in the myocardium, which colocalized with the ischemic area. Late phase enhancement persisted 5 and 24 hours after reperfusion. Similarly, the use of MBP and MBE, comprising antibodies specific for P- and E-selectin, respectively, showed high late-phase enhancement within the ischemic area compared with remote myocardial tissue. Two and 5 hours after ischemia has resolved, a persistent expression of these 2 selectins was detected. After 24 hours of reperfusion, only MBE produced late phase enhancement within the ischemic myocardium. Immunohistochemical findings revealed that both P- and E-selectin were expressed and accessible on the surface of the activated endothelium 2 and 5 hours after the acute ischemic event, whereas only E-selectin remained accessible after 24 hours.
CONCLUSIONS: Ultrasound molecular imaging of transient myocardial ischemia using dual selectin-targeted UCA is able to monitor the time course of expression of selectins after resolution of the ischemic event, paving the way for a large clinical diagnostic window.
MATERIAL AND METHODS: Transient (20 minutes) myocardial ischemia of rat heart was produced by ligation of the left anterior descending coronary artery ligation followed by 2-, 5-, or 24-hour reperfusion. Imaging of the transient ischemic event was achieved by the use of MB(selectin). Performance of this clinically translatable targeted UCA was compared with that of antibody-targeted streptavidin MBs. Finally, immunohistochemistry staining of rat myocardial ischemic tissue was performed to assess expression of selectins accessible to targeted UCA.
RESULTS: In rats subjected to myocardial ischemia (20 minutes) followed by reperfusion (2 hours), injection of MB(selectin) produced high late phase (ie, 10-minute postinjection) ultrasound molecular imaging enhancement in the myocardium, which colocalized with the ischemic area. Late phase enhancement persisted 5 and 24 hours after reperfusion. Similarly, the use of MBP and MBE, comprising antibodies specific for P- and E-selectin, respectively, showed high late-phase enhancement within the ischemic area compared with remote myocardial tissue. Two and 5 hours after ischemia has resolved, a persistent expression of these 2 selectins was detected. After 24 hours of reperfusion, only MBE produced late phase enhancement within the ischemic myocardium. Immunohistochemical findings revealed that both P- and E-selectin were expressed and accessible on the surface of the activated endothelium 2 and 5 hours after the acute ischemic event, whereas only E-selectin remained accessible after 24 hours.
CONCLUSIONS: Ultrasound molecular imaging of transient myocardial ischemia using dual selectin-targeted UCA is able to monitor the time course of expression of selectins after resolution of the ischemic event, paving the way for a large clinical diagnostic window.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app