We have located links that may give you full text access.
CONTROLLED CLINICAL TRIAL
JOURNAL ARTICLE
RANDOMIZED CONTROLLED TRIAL
Changes in maxillary incisor dental pulp blood flow during intrusion by mini-implants.
Acta Odontologica Scandinavica 2014 October
AIM: The aim of this clinical study was to identify changes in pulpal blood flow (PBF) in human central incisors resulting from short- and long-term intrusive orthodontic forces from mini-implants.
MATERIALS AND METHODS: A total of 40 sound upper central and lateral incisors in 20 patients scheduled for intrusion for orthodontic reasons were divided into two groups. From each group, 20 teeth were subjected to intrusive force from mini-implants (Group 1 = Light Force: 40 g; Group 2 = Heavy Force: 120 g), whereas the remaining 20 contralateral teeth were not subjected to forces from mini-implants and served as controls. Laser-Doppler flowmetry (LDF) measurements were recorded at baseline and at 3 days and 3 weeks following intrusion.
RESULTS: PBF decreased significantly at 3 days (Light Force Group: 7.72 ± 0.50; Heavy Force Group: 7.72 ± 0.52) and then increased towards baseline at 3 weeks (Light Force Group: 10.37 ± 0.58; Heavy Force Group: 10.31 ± 0.45) following intrusion.
CONCLUSIONS: In other words, despite slight regressive changes in pulpal tissue in the short-term, PBF improved after 3 weeks following intrusion by mini-implants, indicating that the changes observed in PBF is reversible, even following radical incisor intrusion.
MATERIALS AND METHODS: A total of 40 sound upper central and lateral incisors in 20 patients scheduled for intrusion for orthodontic reasons were divided into two groups. From each group, 20 teeth were subjected to intrusive force from mini-implants (Group 1 = Light Force: 40 g; Group 2 = Heavy Force: 120 g), whereas the remaining 20 contralateral teeth were not subjected to forces from mini-implants and served as controls. Laser-Doppler flowmetry (LDF) measurements were recorded at baseline and at 3 days and 3 weeks following intrusion.
RESULTS: PBF decreased significantly at 3 days (Light Force Group: 7.72 ± 0.50; Heavy Force Group: 7.72 ± 0.52) and then increased towards baseline at 3 weeks (Light Force Group: 10.37 ± 0.58; Heavy Force Group: 10.31 ± 0.45) following intrusion.
CONCLUSIONS: In other words, despite slight regressive changes in pulpal tissue in the short-term, PBF improved after 3 weeks following intrusion by mini-implants, indicating that the changes observed in PBF is reversible, even following radical incisor intrusion.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app