Bioanalytical method development and validation of alimemazine in human plasma by LC-MS/MS and its application in bioequivalence studies.

BACKGROUND: The use of anti-histaminic agents has been increased significantly from last decades and till now no method is available for quantitation of ALZ in human plasma which can be applied in a bioequivalence study using LC-MS/MS.

OBJECTIVE: The present study is concerned with the development and validation of ALZ in human plasma by high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS).

MATERIALS AND METHODS: Sample preparation involved the extraction with liquid-liquid extraction method by using ethyl acetate as an organic solvent. Chromatographic separation was performed on Atlantis® T3 5 μm 4.6 mm × 150 mm column with the mobile phase consisting of acetonitrile: (10 mm ammonium formate buffer: Formic acid: 99.9:00.1 v/v) 50:50 v/v. The interface used with the application programming interface 4000 LC-MS/MS was a turbo ion spray in which positive ions were measured in multiple reaction monitoring mode. The precursor to product ions transition of m/z 299.30 → 100.20 amu and 305.30 → 106.30 amu were used for ALZ and ALZ D6 respectively.

RESULTS: The method was validated over the concentration range of 20.013-10006.551 pg/mL. The mean percent recovery of ALZ was found 77.771% with a precision of 7.71% and the lower limit of quantification was 20.013 pg/mL. The intra- and inter-day precision of the method at three concentrations was 0.98-4.50% and 1.57-5.72% while the intra- and inter-day % accuracy was 99.02-93.82% and 101.78-106.96%. Stability of compounds was established in a series of stability studies. The application of this method was demonstrated in the bioequivalence study and was found suitable in a study of sample size as big as 30 enrolled volunteers.

CONCLUSION: For the very first time, a sensitive, selective and robust Liquid Chromatography- Mass Spectrometry method for the determination of alimemazine (ALZ) in human plasma has been developed and validated using ALZ D6 as an internal standard.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app