Insertion of PICCs with minimum number of lumens reduces complications and costs.
Journal of the American College of Radiology : JACR 2013 November
BACKGROUND: Inappropriate catheter requests at the McGill University Health Centre (MUHC) led to significantly increased costs and early catheter malfunction or infection. Dual-lumen catheters were often requested and inserted when only a single lumen was required, and inappropriate catheter care on the wards led to early infection or thrombosis.
METHODS: A full-time registered nurse was hired to analyze and transform the vascular access program of the MUHC. Catheter selection was streamlined on the basis of clinical unit need. Clinical and cost data were collected between May 2011 and January 2012.
RESULTS: Requests for vascular access at the MUHC have been standardized and centralized. Single-lumen catheters are inserted unless a specific indication for a dual-lumen catheter is provided. To date, data have been collected on >4,000 catheter insertions, both before and after the switch to the single-lumen program. Dual-lumen catheters have been required in only 50% of cases. Reinsertion rates have decreased, leading to the first year-over-year reduction in peripherally inserted central venous catheter insertion since data collection began in 2002. The program has also resulted in significant reductions in central line-associated bloodstream infection and catheter-related thrombosis. Decreased maintenance and reinsertion costs have led to overall savings for the MUHC of approximately $1.1 million.
METHODS: A full-time registered nurse was hired to analyze and transform the vascular access program of the MUHC. Catheter selection was streamlined on the basis of clinical unit need. Clinical and cost data were collected between May 2011 and January 2012.
RESULTS: Requests for vascular access at the MUHC have been standardized and centralized. Single-lumen catheters are inserted unless a specific indication for a dual-lumen catheter is provided. To date, data have been collected on >4,000 catheter insertions, both before and after the switch to the single-lumen program. Dual-lumen catheters have been required in only 50% of cases. Reinsertion rates have decreased, leading to the first year-over-year reduction in peripherally inserted central venous catheter insertion since data collection began in 2002. The program has also resulted in significant reductions in central line-associated bloodstream infection and catheter-related thrombosis. Decreased maintenance and reinsertion costs have led to overall savings for the MUHC of approximately $1.1 million.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app