COMPARATIVE STUDY
JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

Functional outcome, revision rates and mortality after primary total hip replacement--a national comparison of nine prosthesis brands in England.

BACKGROUND: The number of prosthesis brands used for hip replacement has increased rapidly, but there is little evidence on their effectiveness. We compared patient-reported outcomes, revision rates, and mortality for the three most frequently used brands within each prosthesis type: cemented (Exeter V40 Contemporary, Exeter V40 Duration and Exeter V40 Elite Plus Ogee), cementless (Corail Pinnacle, Accolade Trident, and Taperloc Exceed), and hybrid (Exeter V40 Trilogy, Exeter V40 Trilogy, and CPT Trilogy).

METHODS AND FINDINGS: We used three national databases of patients who had hip replacements between 2008 and 2011 in the English NHS to compare functional outcome (Oxford Hip Score (OHS) ranging from 0 (worst) to 48 (best)) in 43,524 patients at six months. We analysed revisions and mortality in 187,201 patients. We used multiple regression to adjust for pre-operative differences. Prosthesis type had an impact on post-operative OHS and revision rates (both p<0.001). Patients with hybrid prostheses had the best functional outcome (mean OHS 39.4, 95%CI 39.1 to 39.7) and those with cemented prostheses the worst (37.7, 37.3 to 38.1). Patients with cemented prostheses had the lowest reported 5-year revision rates (1.3%, 1.2% to 1.4%) and those with cementless prostheses the highest (2.2%, 2.1% to 2.4%). Differences in mortality according to prosthesis type were small and not significant (p = 0.06). Functional outcome varied according to brand among cemented (p = 0.05, with Exeter V40 Duration having the best) and cementless prostheses (p = 0.01, with Corail Pinnacle having the best). Revision rates varied according to brand among hybrids (p = 0.05, with Exeter V40 Trident having the lowest).

CONCLUSIONS: Functional outcomes were better with cementless cups and revision rates were lower with cemented stems, which underlies the good overall performance of hybrids. The hybrid Exeter V40 Trident seemed to produce the best overall results. This brand should be considered as a benchmark in randomised trials.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app