We have located links that may give you full text access.
Validated spectrophotometric methods for the simultaneous determination of telmisartan and atorvastatin in bulk and tablets.
Pharmaceutical Methods 2012 July
AIM: Three simple, accurate, and reproducible spectrophotometric methods have been developed and validated for simultaneous estimation of telmisartan (TELM) atorvastatin (ATV) in combined tablet dosage form.
MATERIALS AND METHODS: The first method is based on first-order derivative spectroscopy. The sampling wavelengths were 223 nm (zero crossing of TELM) where ATV showed considerable absorbance and 272 nm (zero crossing of ATV) where TELM showed considerable absorbance. The second method Q-analysis (absorbance ratio), involves formation of Q-absorbance equation using respective absorptivity values at 280.9 nm (isobestic point) and 296.0 nm (λmax of TELM). The third method involves determination using multicomponent mode method; sampling wavelengths selected were 296.0 and 246.9 nm.
RESULTS: TELM and ATV followed linearity in the concentration range of 5-40 and 4-32 μg/ml for method I, 5-30 μg/ml and 2-24 μg/ml for method II and III, respectively. Mean recoveries for all three methods were found satisfactory. All methods were validated according to International Conference on Harmonization Q2B guidelines.
CONCLUSION: The developed methods are simple, precise, rugged, and economical. The utility of methods has been demonstrated by analysis of commercially available tablet dosage form.
MATERIALS AND METHODS: The first method is based on first-order derivative spectroscopy. The sampling wavelengths were 223 nm (zero crossing of TELM) where ATV showed considerable absorbance and 272 nm (zero crossing of ATV) where TELM showed considerable absorbance. The second method Q-analysis (absorbance ratio), involves formation of Q-absorbance equation using respective absorptivity values at 280.9 nm (isobestic point) and 296.0 nm (λmax of TELM). The third method involves determination using multicomponent mode method; sampling wavelengths selected were 296.0 and 246.9 nm.
RESULTS: TELM and ATV followed linearity in the concentration range of 5-40 and 4-32 μg/ml for method I, 5-30 μg/ml and 2-24 μg/ml for method II and III, respectively. Mean recoveries for all three methods were found satisfactory. All methods were validated according to International Conference on Harmonization Q2B guidelines.
CONCLUSION: The developed methods are simple, precise, rugged, and economical. The utility of methods has been demonstrated by analysis of commercially available tablet dosage form.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app