Thyroid functions after contrast agent administration for coronary angiography: a prospective observational study in euthyroid patients.
Anatolian Journal of Cardiology : AKD 2013 June
OBJECTIVE: This study aims to investigate long-term effects of iodinated radiographic contrast media used for coronary angiography (CAG) on the thyroid function in euthyroid patients.
METHODS: In a prospective observational cohort study, nonionic iodinated contrast material was electively used in 101 patients for coronary angiography. The patients were recruited without age restrictions and, at baseline, all had normal levels of free triiodothyronine (FT3), free thyroxine (FT4) and thyrotropin (TSH). The morphology of the thyroid was evaluated by thyroid ultrasonography (USG). Four and eight weeks after CAG, serum TSH, FT3 and FT4 levels were assessed.
RESULTS: Compared to a mean baseline level of 1.49 (25%-75%, range 13-2.21), follow-up TSH levels decreased significantly to 1.45 (25%-75%, range 1.98-0.92, p=0.017) and 1.40 (25%-75%, range 1.89-0.87, p=0.003) at 4 weeks and 8 weeks, respectively (p=0.008). No significant diffe-rence was observed in TSH levels between the 4th and 8th weeks (p=0.833).
CONCLUSION: Iodinated radiographic contrast agents may cause subclinical hyperthyroidism in euthyroid patients undergoing CAG.
METHODS: In a prospective observational cohort study, nonionic iodinated contrast material was electively used in 101 patients for coronary angiography. The patients were recruited without age restrictions and, at baseline, all had normal levels of free triiodothyronine (FT3), free thyroxine (FT4) and thyrotropin (TSH). The morphology of the thyroid was evaluated by thyroid ultrasonography (USG). Four and eight weeks after CAG, serum TSH, FT3 and FT4 levels were assessed.
RESULTS: Compared to a mean baseline level of 1.49 (25%-75%, range 13-2.21), follow-up TSH levels decreased significantly to 1.45 (25%-75%, range 1.98-0.92, p=0.017) and 1.40 (25%-75%, range 1.89-0.87, p=0.003) at 4 weeks and 8 weeks, respectively (p=0.008). No significant diffe-rence was observed in TSH levels between the 4th and 8th weeks (p=0.833).
CONCLUSION: Iodinated radiographic contrast agents may cause subclinical hyperthyroidism in euthyroid patients undergoing CAG.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app