Medication safety improves after implementation of positive patient identification.
OBJECTIVE: To report the incidence and severity of medication safety events before and after initiation of barcode scanning for positive patient identification (PPID) in a large teaching hospital.
METHODS: Retrospective analysis of data from an existing safety reporting system with anonymous and non-punitive self-reporting. Medication safety events were categorized as "near-miss" (unsafe conditions or caught before reaching the patient) or reaching the patient, with requisite additional monitoring or treatment. Baseline and post-PPID implementation data on events per 1,000,000 drug administrations were compared by chi-square with p<0.05 considered significant.
RESULTS: An average of 510,541 doses were dispensed each month in 2008. Total self-reported medication errors initially increased from 20 per million doses dispensed pre-barcoding (first quarter 2008) to 38 per million doses dispensed immediately post-intervention (last quarter 2008), but errors reaching the patient decreased from 3.26 per million to 0.8 per million despite the increase in "near-misses". A number of process issues were identified and improved, including additional training and equipment, instituting ParX scanning when filling Pyxis machines, and lobbying for a manufacturing change in how bar codes were printed on bags of intravenous solutions to reduce scanning failures.
CONCLUSION: Introduction of barcoding of medications and patient wristbands reduced serious medication dispensing errors reaching the patient, but temporarily increased the number of "near-miss" situations reported. Overall patient safety improved with the barcoding and positive patient identification initiative. These results have been sustained during the 18 months following full implementation.
METHODS: Retrospective analysis of data from an existing safety reporting system with anonymous and non-punitive self-reporting. Medication safety events were categorized as "near-miss" (unsafe conditions or caught before reaching the patient) or reaching the patient, with requisite additional monitoring or treatment. Baseline and post-PPID implementation data on events per 1,000,000 drug administrations were compared by chi-square with p<0.05 considered significant.
RESULTS: An average of 510,541 doses were dispensed each month in 2008. Total self-reported medication errors initially increased from 20 per million doses dispensed pre-barcoding (first quarter 2008) to 38 per million doses dispensed immediately post-intervention (last quarter 2008), but errors reaching the patient decreased from 3.26 per million to 0.8 per million despite the increase in "near-misses". A number of process issues were identified and improved, including additional training and equipment, instituting ParX scanning when filling Pyxis machines, and lobbying for a manufacturing change in how bar codes were printed on bags of intravenous solutions to reduce scanning failures.
CONCLUSION: Introduction of barcoding of medications and patient wristbands reduced serious medication dispensing errors reaching the patient, but temporarily increased the number of "near-miss" situations reported. Overall patient safety improved with the barcoding and positive patient identification initiative. These results have been sustained during the 18 months following full implementation.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app