We have located links that may give you full text access.
CONTROLLED CLINICAL TRIAL
JOURNAL ARTICLE
MULTICENTER STUDY
MediGuide in supraventricular tachycardia: initial experience from a multicentre registry.
AIMS: Currently, fluoroscopy-based catheter visualization is the standard modality in invasive electrophysiological procedures. Recently a new technology for non-fluoroscopic visualization of diagnostic (since 2010) and ablation catheters (since May 2012) has been introduced. The MediGuide™-Technology (MediGuide) projects catheter tips on prerecorded cine loops in a high time resolution.
METHODS AND RESULTS: We report on MediGuide-based supraventricular tachycardia (SVT) cases [atrioventricular nodal reentry tachycardia (AVNRT), atrioventricular reentry tachycardia (AVRT), Wolff-Parkinson-White syndrome (WPW), ectopic atrial tachycardia (EAT) and typical atrial flutter) from two European centres. In all patients, diagnostic and/or ablation catheters with a special sensor were used to perform the ablation procedures. All procedural data such as acute success, duration of the procedure, fluoroscopy time, and dose and patients' characteristics were analyzed and compared with conventionally ablated patients (n = 1865). Procedure-related complications during the hospital stay were recorded. A total of 24 consecutive patients were analyzed: no significant difference to the control group was seen in the baseline characteristics. The MediGuide patients were predominantly male (66%), aged 58 ± 14 years and were ablated for 6 AVNRT (25%), 4 AVRT/WPW (17%), 1 EAT (4%), and 13 typical atrial flutter (54%). The acute success rate was 100% (98% in the control group, n.s.). The median fluoroscopy time was 0.5 ± 1.4 min (10.2 ± 9.6 in the control group, P < 0.001), the median fluoroscopy dose was 187 ± 554 cGy cm(2) (996 ± 2593 cGy cm(2), P < 0.05). Mean procedure time was 70 ± 25 min (60 ± 36 min, n.s.). No complications during the hospital stay were recorded.
CONCLUSION: In several different forms of supraventricular tachycardias the MediGuide-Technology contributed to a dramatic reduction in irradiation exposure. With a median fluoroscopy time of 30 s all SVT cases were effectively performed with no complications; the fluoroscopy burden can be significantly reduced not only for the patient but also for the nurses and the physicians performing the case. The overall procedure times are not prolonged due to the use of MediGuide Technology compared with a control group of >1800 patients undergoing conventional ablation procedures.
METHODS AND RESULTS: We report on MediGuide-based supraventricular tachycardia (SVT) cases [atrioventricular nodal reentry tachycardia (AVNRT), atrioventricular reentry tachycardia (AVRT), Wolff-Parkinson-White syndrome (WPW), ectopic atrial tachycardia (EAT) and typical atrial flutter) from two European centres. In all patients, diagnostic and/or ablation catheters with a special sensor were used to perform the ablation procedures. All procedural data such as acute success, duration of the procedure, fluoroscopy time, and dose and patients' characteristics were analyzed and compared with conventionally ablated patients (n = 1865). Procedure-related complications during the hospital stay were recorded. A total of 24 consecutive patients were analyzed: no significant difference to the control group was seen in the baseline characteristics. The MediGuide patients were predominantly male (66%), aged 58 ± 14 years and were ablated for 6 AVNRT (25%), 4 AVRT/WPW (17%), 1 EAT (4%), and 13 typical atrial flutter (54%). The acute success rate was 100% (98% in the control group, n.s.). The median fluoroscopy time was 0.5 ± 1.4 min (10.2 ± 9.6 in the control group, P < 0.001), the median fluoroscopy dose was 187 ± 554 cGy cm(2) (996 ± 2593 cGy cm(2), P < 0.05). Mean procedure time was 70 ± 25 min (60 ± 36 min, n.s.). No complications during the hospital stay were recorded.
CONCLUSION: In several different forms of supraventricular tachycardias the MediGuide-Technology contributed to a dramatic reduction in irradiation exposure. With a median fluoroscopy time of 30 s all SVT cases were effectively performed with no complications; the fluoroscopy burden can be significantly reduced not only for the patient but also for the nurses and the physicians performing the case. The overall procedure times are not prolonged due to the use of MediGuide Technology compared with a control group of >1800 patients undergoing conventional ablation procedures.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app