Add like
Add dislike
Add to saved papers

Loss of lordosis and clinical outcomes after anterior cervical fusion with dynamic rotational plates.

PURPOSE: The cervical dynamic rotational plating system may induce bone graft subsidence, so it may cause loss of cervical lordosis. However there were few studies for alignments of cervical spines influencing the clinical results after using dynamic rotational plates. The purpose is to evaluate the effect of graft subsidence on cervical alignments due to the dynamic rotational cervical plates and correlating it with the clinical outcomes of patients undergoing anterior cervical fusion.

MATERIALS AND METHODS: Thirty-three patients with disease or fracture underwent anterior cervical decompression and fusion using a dynamic rotational plate. The presence and extent of implant complications, graft subsidence, loss of lordosis were identified and Visual Analog Scale score (VAS score), Japanese Orthopaedic Association score (JOA score), clinical outcomes based on Odom's criteria were recorded.

RESULTS: Fusion was achieved without implant complications in all cases. The mean graft subsidence at 6 months after the surgery was 1.46 mm. The lordotic changes in local cervical angles were 5.85° which was obtained postoperatively. VAS score for radicular pain was improved by 5.19 and the JOA score was improved by 3. Clinical outcomes based on Odom's criteria showed sixteen excellent, ten good and two satisfactory results. There was no significant relationship between clinical outcomes and changes in the cervical angles.

CONCLUSION: Dynamic rotational anterior cervical plating provides comparable clinical outcomes to that of the reports of former static cervical platings. The loss of lordosis is related to the amount of graft settling but it is not related to the clinical outcomes.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app