We have located links that may give you full text access.
Comparative Study
Journal Article
Relationship of hypertropia and excyclotorsion in superior oblique palsy.
Korean Journal of Ophthalmology : KJO 2013 Februrary
PURPOSE: To evaluate the correlation between hypertropia and excyclotorsion in acquired superior oblique palsy (SOP).
METHODS: Thirty-one patients with acquired unilateral SOP were recruited for this study. The torsional angle of each patient was assessed via one objective method (fundus photography) and two subjective methods (double Maddox rod test and major amblyoscope). The patient population was divided into two groups (concordance group, n = 19 and discordance group, n = 12) according to the correspondence between the hypertropic eye (paralytic eye) and the more extorted eye (non-fixating eye), which was evaluated by fundus photography.
RESULTS: The mean value of objective torsion was 5.09° ± 3.84°. The subjective excyclotorsion degrees were 5.18° ± 4.11° and 3.65° ± 1.93° as measured by double Maddox rod test and major amblyoscope, respectively. Hypertropia and the excyclotorsional angle did not differ significantly between the groups (p = 0.257). Although no correlation was found in the discordance group, the concordance group showed a significant and positive correlation between hypertropia and excyclotorsion (p = 0.011).
CONCLUSIONS: Torsional deviation was not related to hypertropia. However, in the concordance patients in whom the hypertropic eye showed excyclotorsion, a significant positive correlation was found between hypertropia and excyclotorsion.
METHODS: Thirty-one patients with acquired unilateral SOP were recruited for this study. The torsional angle of each patient was assessed via one objective method (fundus photography) and two subjective methods (double Maddox rod test and major amblyoscope). The patient population was divided into two groups (concordance group, n = 19 and discordance group, n = 12) according to the correspondence between the hypertropic eye (paralytic eye) and the more extorted eye (non-fixating eye), which was evaluated by fundus photography.
RESULTS: The mean value of objective torsion was 5.09° ± 3.84°. The subjective excyclotorsion degrees were 5.18° ± 4.11° and 3.65° ± 1.93° as measured by double Maddox rod test and major amblyoscope, respectively. Hypertropia and the excyclotorsional angle did not differ significantly between the groups (p = 0.257). Although no correlation was found in the discordance group, the concordance group showed a significant and positive correlation between hypertropia and excyclotorsion (p = 0.011).
CONCLUSIONS: Torsional deviation was not related to hypertropia. However, in the concordance patients in whom the hypertropic eye showed excyclotorsion, a significant positive correlation was found between hypertropia and excyclotorsion.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app