COMPARATIVE STUDY
JOURNAL ARTICLE
Add like
Add dislike
Add to saved papers

Comparison of two different generations of "NIRS" devices and transducers in healthy volunteers and ICU patients.

The purpose of this study is to compare Near Infrared Spectroscopy (NIRS) thenar eminence parameters obtained with 2 different devices from the same manufacturer (InSpectra Models 325 and 650, Hutchinson Tech, Min USA), and 2 different probes (15 vs. 25 mm spacing), in healthy volunteers (HV) and ICU patients. Prospective, observational study in ICU setting. Simultaneous, cross over NIRS inter-device comparison and comparison between different probes (25 vs. 15 mm spacing) were done at baseline and during vascular occlusion tests (VOTs). Forty patients (19 septic shock, 21 trauma), and 29 HV were included. NIRS inter-device comparison showed similar baseline StO(2) values in HV and patients. The VOT result were significantly different for minimal StO(2) value reached during VOT (StO(2min)) (intraclass concordance coefficient (ICC) = 0.18), the occlusion slope (ICC = 0.16) and the reperfusion slope (StO(2reperf)) (ICC = 0.26). The probe comparison was also significantly different for VOT parameters (StO(2min) (ICC = 0.43), occlusion (ICC = 0.50) and StO(2reperf) (ICC = 0.48). The low concordance, poor agreement and large bias (ICC and Bland & Altman) observed, were related both to the device used and the probe spacing. StO(2) data obtained with NIRS model 650 and 15 mm probe differ from values obtained with the previous device (325 and probe spacing 25 or 15 mm). This difference is not related to the population tested, but to the device and probe spacing. As a consequence, despite similar trends for variations between HV and patients during VOT, threshold and predictive values for outcome should be revisited with the new device before the acceptance for routine clinical use.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app