Effect of a novel fixation method for spinal cord stimulators.

INTRODUCTION: Spinal cord stimulation is a well-established treatment for recalcitrant pain syndromes such as failed back surgery syndrome. Techniques minimizing surgical time and incision size and increasing lead stability are of great value to both the patient and implanting physician. We present a consecutive case series review of ten permanent percutaneous spinal cord implants utilizing a novel lead fixation device. The purpose of this case series review is to present initial findings of the minimized incision size and thoughts surrounding the new device and technique.

CASE SERIES REPORT: Ten cases were performed utilizing the new device (fiXate) and technique. Incision size was dictated by adequate visualization of the fascial stratum as well as technical working space required for lead fixation and redirection to the generator pocket. Each spinal cord stimulator lead was affixed to the thoracodorsal fascia utilizing the novel device.

DISCUSSION: In this consecutive series, the average midline incision size was 2.2 cm (range = 1.9-2.6 cm) which is greatly minimized through the use of the device. Not only may fiXate directly affect incision size, operating room and anesthesia time may also be lessened due to the semiautomated nature of the device. Of the cases performed, there were no complications or adverse events. Of note, there have been no reports of lead migrations during this case series, the average follow-up time being 18 weeks (range 11-26 weeks).

CONCLUSION: These data suggest a new method of fixation can be utilized for percutaneous spinal cord stimulation that allows a reduction in incision size. Intuitively, reduction in incision size is relevant with regard to tissue morbidity and may also have implications with regard to infection. Use of the device may also reduce operating room and anesthesia time as well as provide greater stability than standard suture.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app