We have located links that may give you full text access.
Case Reports
Journal Article
Refractive and topographic errors in topography-guided ablation produced by epithelial compensation predicted by 3D Artemis VHF digital ultrasound stromal and epithelial thickness mapping.
Journal of Refractive Surgery 2012 September
PURPOSE: To describe and quantify the errors inherent to topography-guided ablation of irregular corneas due to natural epithelial thickness compensatory remodeling.
METHODS: Artemis very high-frequency (VHF) digital ultrasound scanning (ArcScan Inc) was performed on a cornea that had undergone radial keratotomy with inferior and superior trapezoidal keratotomies, resulting 27 years later in high irregular astigmatism (+6.50 -8.00 × 101) and severe loss of corrected distance visual acuity (CDVA) to 20/50. The epithelial thickness profile was highly irregular, masking a significant proportion of the true stromal irregularity from front corneal surface topography, which would have resulted in significant inaccuracies had a topography-guided ablation been performed. The stromal ablation pattern of a transepithelial phototherapeutic keratectomy (PTK) ablation was modeled, which appeared logically to reduce the areas of abnormal stromal surface elevation and resembled a hyperopic astigmatic ablation of approximately 3.50 diopters of cylinder. Artemis-assisted transepithelial PTK was performed to target the stromal irregularity masked by epithelium.
RESULTS: Artemis-assisted transepithelial PTK induced a refractive change similar to that predicted (+2.24 -3.97 × 120), demonstrating the refractive shift produced by the epithelium. The epithelial thickness profile became relatively regular and CDVA returned to 20/20⁻². Two topography wavefront-guided ablations were performed to correct the remaining topographic irregularity and refractive error, resulting in a near plano refraction, significantly lower higher order aberrations, and CDVA of 20/20⁺².
CONCLUSIONS: A knowledge of stromal surface shape and power shift produced by epithelial thickness profile alterations after corneal surgery has the potential of improving the efficacy and safety of custom corneal ablation.
METHODS: Artemis very high-frequency (VHF) digital ultrasound scanning (ArcScan Inc) was performed on a cornea that had undergone radial keratotomy with inferior and superior trapezoidal keratotomies, resulting 27 years later in high irregular astigmatism (+6.50 -8.00 × 101) and severe loss of corrected distance visual acuity (CDVA) to 20/50. The epithelial thickness profile was highly irregular, masking a significant proportion of the true stromal irregularity from front corneal surface topography, which would have resulted in significant inaccuracies had a topography-guided ablation been performed. The stromal ablation pattern of a transepithelial phototherapeutic keratectomy (PTK) ablation was modeled, which appeared logically to reduce the areas of abnormal stromal surface elevation and resembled a hyperopic astigmatic ablation of approximately 3.50 diopters of cylinder. Artemis-assisted transepithelial PTK was performed to target the stromal irregularity masked by epithelium.
RESULTS: Artemis-assisted transepithelial PTK induced a refractive change similar to that predicted (+2.24 -3.97 × 120), demonstrating the refractive shift produced by the epithelium. The epithelial thickness profile became relatively regular and CDVA returned to 20/20⁻². Two topography wavefront-guided ablations were performed to correct the remaining topographic irregularity and refractive error, resulting in a near plano refraction, significantly lower higher order aberrations, and CDVA of 20/20⁺².
CONCLUSIONS: A knowledge of stromal surface shape and power shift produced by epithelial thickness profile alterations after corneal surgery has the potential of improving the efficacy and safety of custom corneal ablation.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app