We have located links that may give you full text access.
Comparative Study
Journal Article
Research Support, Non-U.S. Gov't
Penetrating keratoplasty using femtosecond laser-enabled keratoplasty with zig-zag incisions versus a mechanical trephine in patients with keratoconus.
British Journal of Ophthalmology 2012 September
BACKGROUND/AIMS: This paper will compare the visual outcomes of two different penetrating keratoplasty (PKP) techniques in patients with keratoconus. It is a retrospective comparative surgical case series of 116 keratoconus patients (137 eyes) who had PKP at the Cornea Eye Institute, Beverly Hills, California, USA.
METHODS: 56 keratoconus patients (66 eyes) underwent femtosecond laser-enabled keratoplasty (FLEK) with a zig-zag incision configuration. Their visual parameters were compared with those of 60 patients (71 eyes) who had traditional blade mechanical trephination PKP. The range of follow-up was between 3 and 6 months. The main outcome measures included uncorrected visual acuity and best spectacle-corrected visual acuity (BSCVA), manifest refractive spherical equivalent and topographically determined astigmatism.
RESULTS: BSCVA was significantly better as early as 3 months postoperatively (p=0.001) in the FLEK group. Visual recovery to 20/40 after 3 months was significantly better in the FLEK group (p<0.001). Topographic astigmatism was lower in the FLEK group, but the difference between the two groups reached significance only at 3 months of follow-up (p=0.001). Postoperative complications noted were not different between the two groups.
CONCLUSIONS: Faster visual recovery and better long-term outcomes were observed in keratoconus patients who had FLEK compared with those who had the mechanical PKP procedure with 6 months of postoperative follow-up.
METHODS: 56 keratoconus patients (66 eyes) underwent femtosecond laser-enabled keratoplasty (FLEK) with a zig-zag incision configuration. Their visual parameters were compared with those of 60 patients (71 eyes) who had traditional blade mechanical trephination PKP. The range of follow-up was between 3 and 6 months. The main outcome measures included uncorrected visual acuity and best spectacle-corrected visual acuity (BSCVA), manifest refractive spherical equivalent and topographically determined astigmatism.
RESULTS: BSCVA was significantly better as early as 3 months postoperatively (p=0.001) in the FLEK group. Visual recovery to 20/40 after 3 months was significantly better in the FLEK group (p<0.001). Topographic astigmatism was lower in the FLEK group, but the difference between the two groups reached significance only at 3 months of follow-up (p=0.001). Postoperative complications noted were not different between the two groups.
CONCLUSIONS: Faster visual recovery and better long-term outcomes were observed in keratoconus patients who had FLEK compared with those who had the mechanical PKP procedure with 6 months of postoperative follow-up.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app