Twenty years' single-center experience with mechanical heart valves: a critical review of anticoagulation policy.

BACKGROUND AND AIM OF THE STUDY: Since January 1990, a variety of mechanical valves (St. Jude Medical, CarboMedics, ATS Medical) have been implanted routinely at the authors' institution. The study aim was to analyze, retrospectively, the 20-year clinical results of those mechanical valves, and to challenge the anticoagulation policy employed over the years.

METHODS: Between January 1990 and December 2008, a total of 2,108 mechanical valves was inserted into 1,887 consecutive patients (1,346 aortic, 725 mitral, 27 tricuspid, 10 pulmonary). The mean age of the patients was 63 +/- 13.2 years, and the majority (61%) were males. Preoperatively, 71% the patients were in NYHA class > or = III (average 3.01). The most frequent comorbidities included: atrial fibrillation (n = 594), coronary disease (n = 567) and diabetes (n = 398). The follow up (99% complete) totaled 13,721 patient-years (pt-yr), and ranged from 12 to 241 months (average 84 months).

RESULTS: In-hospital mortality was 5.2% (n = 98, 14 valve-related). Of the 629 late deaths, the majority were cardiac (n = 276). Survival (Kaplan-Meier estimation) was significantly better for aortic valve patients compared to mitral or multiple valve replacement (Mantel-Cox, p < 0.0001). The overall linearized incidences (as %/pt-yr) were: valve thrombosis 0.31, thromboembolism 1.08, and bleeding 0.91. However, as repeated events occurred in several patients, the hazard function was not constant. Multivariate analysis (Cox regression model) showed age > 70 years (p < 0.0001), NYHA class > or = III (p < 0.0001), non-sinus rhythm (p = 0.001), concomitant coronary artery bypass grafting (p = 0.008) and higher International Normalized Ratio (INR) values (p = 0.013) as significant risk factors for death, with a trend for redo operations (p = 0.052). Multivariate analysis found variable INR, non-sinus rhythm and NYHA class > II as significant risk factors for thromboembolism, while long-acting coumadin and NYHA class > II were significant risk factors for bleeding.

CONCLUSION: This 20-year experience demonstrated excellent clinical outcomes for patients with mechanical prostheses, with no valve structural failure and an acceptable incidence of adverse events. INR values between 2-2.5 for aortic valve patients, and 3-3.5 for mitral valve patients, yielded the fewest major adverse events.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app