We have located links that may give you full text access.
COMPARATIVE STUDY
JOURNAL ARTICLE
Skin closure with subcuticular absorbable staples after cesarean section is associated with decreased analgesic use.
Archives of Gynecology and Obstetrics 2012 April
PURPOSE: To determine if skin closure with subcuticular absorbable staples at the time of cesarean section is associated with decreased in-hospital analgesic use compared to skin closure with surgical steel staples.
METHODS: A retrospective cohort study was performed between 1 January 2005 and 31 December 2008 comparing in-hospital analgesic use after cesarean section between patients ,who underwent skin closure with surgical steel staples and subcuticular absorbable polyglycolic acid staples.
RESULTS: Eighty-nine subjects were included in the absorbable staple cohort and 95 were included in the steel staple group. There was a 1.5-fold decrease in ketorolac use (p < 0.0001) and a trend toward decreased ibuprofen use in the absorbable staple cohort (p = 0.06). There was no difference in hydrocodone/acetaminophen use between groups (p = 0.89).
CONCLUSIONS: Our results suggest that the use of subcuticular absorbable staples for skin closure at the time of cesarean section may lead to less in-hospital analgesic use, and thereby positively impact a patient's post-operative course. In addition, while reduced analgesic use may represent a small cost savings for each individual patient, there is the potential for significant savings when one considers the large number of cesarean sections performed in the US annually. Prospective studies will be required to assess the full impact of the use of this new skin closure technology.
METHODS: A retrospective cohort study was performed between 1 January 2005 and 31 December 2008 comparing in-hospital analgesic use after cesarean section between patients ,who underwent skin closure with surgical steel staples and subcuticular absorbable polyglycolic acid staples.
RESULTS: Eighty-nine subjects were included in the absorbable staple cohort and 95 were included in the steel staple group. There was a 1.5-fold decrease in ketorolac use (p < 0.0001) and a trend toward decreased ibuprofen use in the absorbable staple cohort (p = 0.06). There was no difference in hydrocodone/acetaminophen use between groups (p = 0.89).
CONCLUSIONS: Our results suggest that the use of subcuticular absorbable staples for skin closure at the time of cesarean section may lead to less in-hospital analgesic use, and thereby positively impact a patient's post-operative course. In addition, while reduced analgesic use may represent a small cost savings for each individual patient, there is the potential for significant savings when one considers the large number of cesarean sections performed in the US annually. Prospective studies will be required to assess the full impact of the use of this new skin closure technology.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app