OBJECTIVES: The purpose of this study was to determine the accuracy of sonographic diagnosis of ovarian torsion and the predictive value of typical sonographic signs.
METHODS: The study included 63 women attending an ultrasound unit of a tertiary obstetrics and gynecology department in 2002 through 2008 who had suspected ovarian torsion on sonography and subsequently underwent laparoscopy.
RESULTS: Sonography had diagnostic accuracy of 74.6% for ovarian torsion. Abnormal ovarian blood flow and the presence of free fluid were the most diagnostically accurate isolated sonographic signs (positive predictive values, 80.0% and 89.2%, respectively; negative predictive values, 46.2% and 46.2%). Using combinations of sonographic signs yielded higher specificity and positive predictive values and lower sensitivity and negative predictive values for ovarian torsion. The diagnostic accuracy was largely affected by the ultrasound operator (mean ± SD, 78.8% ± 16.0%; range, 60.0%-100%).
CONCLUSIONS: In the setting of a specialized ultrasound unit, sonographic diagnosis of ovarian torsion had high (74.6%) accuracy compared with previous reports. The absence of typical sonographic signs does not rule out ovarian torsion, especially when the clinical presentation is suggestive. Basing assessments on multiple sonographic signs, including Doppler evaluation, increases the diagnostic specificity.
METHODS: The study included 63 women attending an ultrasound unit of a tertiary obstetrics and gynecology department in 2002 through 2008 who had suspected ovarian torsion on sonography and subsequently underwent laparoscopy.
RESULTS: Sonography had diagnostic accuracy of 74.6% for ovarian torsion. Abnormal ovarian blood flow and the presence of free fluid were the most diagnostically accurate isolated sonographic signs (positive predictive values, 80.0% and 89.2%, respectively; negative predictive values, 46.2% and 46.2%). Using combinations of sonographic signs yielded higher specificity and positive predictive values and lower sensitivity and negative predictive values for ovarian torsion. The diagnostic accuracy was largely affected by the ultrasound operator (mean ± SD, 78.8% ± 16.0%; range, 60.0%-100%).
CONCLUSIONS: In the setting of a specialized ultrasound unit, sonographic diagnosis of ovarian torsion had high (74.6%) accuracy compared with previous reports. The absence of typical sonographic signs does not rule out ovarian torsion, especially when the clinical presentation is suggestive. Basing assessments on multiple sonographic signs, including Doppler evaluation, increases the diagnostic specificity.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app