We have located links that may give you full text access.
COMPARATIVE STUDY
EVALUATION STUDIES
JOURNAL ARTICLE
A 29-gauge atraumatic needle for amniocentesis.
Journal of Perinatal Medicine 2011 July
OBJECTIVE: To compare perforation characteristics of standard 22 G (0.7 mm) to 29 G needle (0.34 mm) for amniocentesis.
METHODS: Seventeen human chorio-amnion membranes were perforated immediately after cesarean section using 22 G needle for spinal anesthesia and 29 G "pencil-point" needles for amniocentesis under in-vitro conditions. Area of perforation was determined using a microscope and volume of fluid leakage was measured over a period of 5 min.
RESULTS: Membrane perforation with the 22 G needle resulted in a mean damaged area of 225,147.4 μm(2), a hole with a mean area of 50,154 μm(2) and amniotic fluid volume passage of 17.5 mL/5 min, whereas the 29 G needle generated a mean damaged area of 114,812.4 μm(2), a hole with an average area of 1382.5 μm(2) and volume passage of 0.28 mL/5 min. These differences were significant.
CONCLUSION: The hole formed by membrane perforation with 29 G "pencil-point" needle for amniocentesis is 36 times smaller, and the amniotic fluid loss is 61 times less than that measured with the 22 G standard needle for spinal anesthesia. Significant reduction of complications following amniocentesis is expected with the 29 G needle.
METHODS: Seventeen human chorio-amnion membranes were perforated immediately after cesarean section using 22 G needle for spinal anesthesia and 29 G "pencil-point" needles for amniocentesis under in-vitro conditions. Area of perforation was determined using a microscope and volume of fluid leakage was measured over a period of 5 min.
RESULTS: Membrane perforation with the 22 G needle resulted in a mean damaged area of 225,147.4 μm(2), a hole with a mean area of 50,154 μm(2) and amniotic fluid volume passage of 17.5 mL/5 min, whereas the 29 G needle generated a mean damaged area of 114,812.4 μm(2), a hole with an average area of 1382.5 μm(2) and volume passage of 0.28 mL/5 min. These differences were significant.
CONCLUSION: The hole formed by membrane perforation with 29 G "pencil-point" needle for amniocentesis is 36 times smaller, and the amniotic fluid loss is 61 times less than that measured with the 22 G standard needle for spinal anesthesia. Significant reduction of complications following amniocentesis is expected with the 29 G needle.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app