We have located links that may give you full text access.
COMPARATIVE STUDY
EVALUATION STUDIES
JOURNAL ARTICLE
Pre-clinical evaluation of a new dental panoramic radiographic system based on tomosynthesis method.
Dento Maxillo Facial Radiology 2011 January
OBJECTIVES: The purpose of the study was to compare the image generated by a classic panoramic machine equipped with a cadmium telluride sensor capable of digital tomosynthesis and special software with images produced by other popular panoramic X-ray machines using a charge-coupled device and native software for image capture.
METHODS: Panoramic images were made using a phantom of a human skull on Planmeca ProMax, Planmeca EC Proline, Kodak 8000 and PC-1000. With the last machine we used the PanoACT® software to adjust the entire arch and to adjust the image in selected regions of interest (ROIs). Ten viewers evaluated the images and provided the viewer data. ANOVA for repeated measures was used to compare the means by pairwise comparisons of means.
RESULTS: The image of the entire arch adjusted by the PanoACT® software was statistically superior to the images produced by other machines. The images generated and individually adjusted by PanoACT® were statistically superior to all other images.
CONCLUSIONS: The image generated by the cadmium telluride sensor has great potential and can be processed to create superior images to those taken with other machines. Furthermore, the ROI individual images enhanced by the PanoACT® were superior to the entire arch adjusted by the same software.
METHODS: Panoramic images were made using a phantom of a human skull on Planmeca ProMax, Planmeca EC Proline, Kodak 8000 and PC-1000. With the last machine we used the PanoACT® software to adjust the entire arch and to adjust the image in selected regions of interest (ROIs). Ten viewers evaluated the images and provided the viewer data. ANOVA for repeated measures was used to compare the means by pairwise comparisons of means.
RESULTS: The image of the entire arch adjusted by the PanoACT® software was statistically superior to the images produced by other machines. The images generated and individually adjusted by PanoACT® were statistically superior to all other images.
CONCLUSIONS: The image generated by the cadmium telluride sensor has great potential and can be processed to create superior images to those taken with other machines. Furthermore, the ROI individual images enhanced by the PanoACT® were superior to the entire arch adjusted by the same software.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app