Transurethral plasma vaporization of the prostate: 3-month functional outcome and complications.

BJU International 2012 August
UNLABELLED: Study Type - Therapy (multi-centre cohort). Level of Evidence 2b.

OBJECTIVE: To evaluate the early functional outcomes of transurethral plasma vaporization of the prostate (TUVis) in a multicentre study.

PATIENTS AND METHODS: A prospective multicentre observational study was conducted in eight urology departments. The inclusion criterion was benign prostatic hyperplasia (BPH) requiring surgical treatment. Patients on anti-coagulant therapy were not excluded. The TUVis procedure was performed according to a classic transurethral resection of the prostate (TURP) scheme following the manufacturer's recommendations. We evaluated subjective functional outcome using self-questionnaires (International Prostate Symptom Score [IPSS] and five-item International Index of Erectile Function [IIEF-5]) and objective criteria (prostate volume, prostate-specific antigen [PSA], uroflowmetry, post residual volume) at baseline and at 1- and 3-month follow-ups. All types of complications were systematically recorded.

RESULTS: Despite 52% of patients receiving anticoagulant therapy before surgery, we reported only 3% with haemorrhagic complications, no blood transfusion, a mean catheterization time of 44 h and a mean postoperative stay of 2.9 nights. No significant change in irrigation time, catheter time or hospital stay was observed in patients with or without anticoagulant therapy. The IPSS and bother scores significantly decreased after the 3-month follow-up (57% and 59%, respectively), but the average remaining prostate volume was 29 cc and the tissue ablation rate was only 0.5 cc/min. Three major complications occurred, consisting of two urinary fistulas and one partial bladder coagulation.

CONCLUSIONS: The TUVis procedure has a proven fast postoperative recovery time, good short-term functional outcome and good haemostatic efficiency. However, the tissue ablation rate was lower than expected and we encountered three major complications, the mechanisms of which remain unclear. Considering the high energy level required to create the plasma effect, the generator, cable and resectoscope must be carefully checked before each procedure.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app