We have located links that may give you full text access.
Evaluation Study
Journal Article
Bedside ocular ultrasound for the detection of retinal detachment in the emergency department.
Academic Emergency Medicine 2010 September
OBJECTIVES: Acute retinal detachments (RD) can be difficult to diagnose and may require emergent intervention. This study was designed to assess the performance of emergency department ocular ultrasound (EOUS) for the diagnosis of RD.
METHODS: This was a prospective, observational study using a convenience sample of emergency department (ED) patients. Physicians performed EOUS for the diagnosis of RD prior to evaluation by an ophthalmologist. The criterion standard was the diagnosis of a RD by the ophthalmologist who was blinded to the results of EOUS.
RESULTS: Fifteen physicians evaluated 48 patients with acute visual changes. Eighteen patients (38%) had RDs and all were correctly identified (true positives). Of the 30 patients (62%) without RD, 25 patients were correctly identified (true negatives), and five patients with vitreous hemorrhages were misidentified as having RDs (false positives). Therefore, the sensitivity and specificity of EOUS for RD were 100% (95% confidence interval [CI] = 78% to 100%) and 83% (95% CI = 65% to 94%), respectively.
CONCLUSIONS: Emergency department ocular ultrasound is sensitive for the diagnosis of RD and may have a role in excluding RD in patients presenting to the ED.
METHODS: This was a prospective, observational study using a convenience sample of emergency department (ED) patients. Physicians performed EOUS for the diagnosis of RD prior to evaluation by an ophthalmologist. The criterion standard was the diagnosis of a RD by the ophthalmologist who was blinded to the results of EOUS.
RESULTS: Fifteen physicians evaluated 48 patients with acute visual changes. Eighteen patients (38%) had RDs and all were correctly identified (true positives). Of the 30 patients (62%) without RD, 25 patients were correctly identified (true negatives), and five patients with vitreous hemorrhages were misidentified as having RDs (false positives). Therefore, the sensitivity and specificity of EOUS for RD were 100% (95% confidence interval [CI] = 78% to 100%) and 83% (95% CI = 65% to 94%), respectively.
CONCLUSIONS: Emergency department ocular ultrasound is sensitive for the diagnosis of RD and may have a role in excluding RD in patients presenting to the ED.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app