PURPOSE: Use of a pediatric airway exchange catheter (PAEC) has been advocated as a potentially useful adjunct for difficult extubations. We evaluated the laryngeal passing ability of a tracheal tube over a PAEC and compared its success rate between adult patients in the sniffing position and adult patients with simulated cervical spine immobilization created using a manual in-line axial stabilization (MIAS) technique.
METHODS: A total of 100 adult patients were randomized into two groups of equal size with respect to position during the simulated reintubation trial: the MIAS position (Group M) and the sniffing position (Group S). After induction of anesthesia, an 11-F PAEC was placed in the trachea under direct laryngoscopic view, and a wire-reinforced tube (with its bevel facing to the left) was gently railroaded over the PAEC and into the trachea. If insertion was impeded, a second attempt was made after rotating the tube 90 degrees counterclockwise. If this also failed, one additional attempt was made using external laryngeal pressure before changing to conventional laryngoscopic intubation.
RESULTS: After the second attempt, the cumulative success rates in Groups M and S were 41.3% and 72.3%, respectively (P = 0.003). After three attempts, the overall success rate was significantly lower in Group M (52.2%) than in Group S (76.6%) (P = 0.018).
CONCLUSION: Owing to the high failure rate of PAEC-guided intubation in patients with simulated cervical spine immobilization, use of a PAEC is not recommended for maintaining continuous airway access after extubation in adult patients with cervical immobility or instability.
METHODS: A total of 100 adult patients were randomized into two groups of equal size with respect to position during the simulated reintubation trial: the MIAS position (Group M) and the sniffing position (Group S). After induction of anesthesia, an 11-F PAEC was placed in the trachea under direct laryngoscopic view, and a wire-reinforced tube (with its bevel facing to the left) was gently railroaded over the PAEC and into the trachea. If insertion was impeded, a second attempt was made after rotating the tube 90 degrees counterclockwise. If this also failed, one additional attempt was made using external laryngeal pressure before changing to conventional laryngoscopic intubation.
RESULTS: After the second attempt, the cumulative success rates in Groups M and S were 41.3% and 72.3%, respectively (P = 0.003). After three attempts, the overall success rate was significantly lower in Group M (52.2%) than in Group S (76.6%) (P = 0.018).
CONCLUSION: Owing to the high failure rate of PAEC-guided intubation in patients with simulated cervical spine immobilization, use of a PAEC is not recommended for maintaining continuous airway access after extubation in adult patients with cervical immobility or instability.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app