EVALUATION STUDIES
JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

Measurement of fetal urine production by three-dimensional ultrasonography in normal pregnancy.

OBJECTIVES: Measurement of fetal urine production may provide a means of evaluating amniotic fluid volume, which is difficult to measure directly, and predicting fetal hypoxia. Although there have been some reports on fetal urine production, most of these have used two-dimensional (2D) ultrasonography to measure bladder volume. Three-dimensional (3D) ultrasonography is, however, known to be superior to 2D ultrasonography in some organ volume measurements. Thus, we undertook this study to measure bladder volumes using 3D ultrasonography and to establish a nomogram of fetal urine production rate (UPR) according to gestational age (GA).

METHODS: One hundred and fifty-four women with a normal singleton pregnancy at 24 to 40 weeks' gestation were enrolled in this cross-sectional study. The women had no medical or obstetric complications affecting amniotic fluid volume. Fetal bladder volume was measured using 3D ultrasound imaging and Virtual Organ Computer-aided AnaLysis (VOCAL) with a rotational angle of 30 degrees and manual surface tracing technique. Bladder volume was measured two or three times within a 5-10-min interval and fetal UPR was calculated from serial measurements. When measurements were performed more than twice, we used the mean rate of calculated UPRs. UPR was then plotted against GA to establish the nomogram.

RESULTS: Fetal UPR increased with GA from a median value of 7.3 mL/h at 24 weeks' gestation to 71.4 mL/h at term, and could be calculated from GA using the formula: Ln(UPR) = - 6.29582 + (0.43924 x GA) + (0.000432 x GA2), r2 = 0.63, P = 0.0046. Growth percentiles of UPR according to age are presented.

CONCLUSIONS: Fetal UPR can be easily measured by 3D ultrasound assessment of bladder volume. This modality may be a promising alternative to conventional methods of amniotic fluid volume measurement such as amniotic fluid index and single deepest pocket, and might be an alternative option for predicting fetal hypoxia.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app