Can dynamic indicators help the prediction of fluid responsiveness in spontaneously breathing critically ill patients?
Intensive Care Medicine 2007 July
OBJECTIVE: To investigate whether the respiratory changes in arterial pulse (DeltaPP) and in systolic pressure (DeltaSP) could predict fluid responsiveness in spontaneously breathing (SB) patients. Because changes in intrathoracic pressure during spontaneous breathing (SB) might be insufficient to modify loading conditions of the ventricles, performances of indicators were also assessed during a forced respiratory maneuver.
DESIGN: Prospective interventional study.
SETTING: A 34-bed university hospital medico-surgical ICU.
PATIENTS AND PARTICIPANTS: Thirty-two SB patients with clinical signs of hemodynamic instability.
INTERVENTION: A 500-ml volume expansion (VE).
MEASUREMENTS AND RESULTS: Cardiac index, assessed using transthoracic echocardiography, increased by at least 15% after VE in 19 patients (responders). At baseline, only dynamic indicators were higher in responders than in nonresponders (13+/-5% vs. 7+/-3%, p=0.003 for DeltaPP and 10+/-4% vs. 6+/-2%, p=0.002 for DeltaSP). Moreover, they significantly decreased after VE (11+/-5% to 6+/-4%, p<0.001 for DeltaPP and 8+/-4% to 6+/-3%, p<0.001 for DeltaSP). DeltaPP and DeltaSP areas under the ROC curve were high (0.81+/-0.08 and 0.82+/-0.08; p=0.888, respectively). A DeltaPP>or=12% predicted fluid responsiveness with high specificity (92%) but poor sensitivity (63%). The forced respiratory maneuver reproducing a dyspneic state decreased the predictive power.
CONCLUSIONS: Due to their lack of sensitivity and their dependence to respiratory status, DeltaPP and DeltaSP are clearly less reliable to predict fluid responsiveness during SB than in mechanically ventilated patients. However, when their baseline value is high without acute right ventricular dysfunction in a participating patient, a positive response to fluid is likely.
DESIGN: Prospective interventional study.
SETTING: A 34-bed university hospital medico-surgical ICU.
PATIENTS AND PARTICIPANTS: Thirty-two SB patients with clinical signs of hemodynamic instability.
INTERVENTION: A 500-ml volume expansion (VE).
MEASUREMENTS AND RESULTS: Cardiac index, assessed using transthoracic echocardiography, increased by at least 15% after VE in 19 patients (responders). At baseline, only dynamic indicators were higher in responders than in nonresponders (13+/-5% vs. 7+/-3%, p=0.003 for DeltaPP and 10+/-4% vs. 6+/-2%, p=0.002 for DeltaSP). Moreover, they significantly decreased after VE (11+/-5% to 6+/-4%, p<0.001 for DeltaPP and 8+/-4% to 6+/-3%, p<0.001 for DeltaSP). DeltaPP and DeltaSP areas under the ROC curve were high (0.81+/-0.08 and 0.82+/-0.08; p=0.888, respectively). A DeltaPP>or=12% predicted fluid responsiveness with high specificity (92%) but poor sensitivity (63%). The forced respiratory maneuver reproducing a dyspneic state decreased the predictive power.
CONCLUSIONS: Due to their lack of sensitivity and their dependence to respiratory status, DeltaPP and DeltaSP are clearly less reliable to predict fluid responsiveness during SB than in mechanically ventilated patients. However, when their baseline value is high without acute right ventricular dysfunction in a participating patient, a positive response to fluid is likely.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app