We have located links that may give you full text access.
Enzyme immunoassay for anti-treponemal IgG: screening or confirmatory test?
Journal of Clinical Pathology 1992 January
AIMS: To review the performance of the Venereal Diseases Research Laboratory (VDRL) test and the Treponema pallidum haemagglutination assay (TPHA) as a combined screen for syphilis to provide a baseline for assessing screening by anti-treponemal IGG EIA.
METHODS: Between 1980 and 1987 all serum samples were screened by both VDRL and TPHA tests. The FTA-ABS test was also used in suspected early primary syphilis, or when one of the other tests was positive. A positive result in a screening test was confirmed by quantitative testing. From 1988 all specimens were screened with an enzyme immunoassay (Captia Syph G) as a single screening test.
RESULTS: Of the 44 primary, 47 secondary, and 38 early latent cases of syphilis, the VDRL and TPHA detected 32 (73%) and 31 (71%) of the primary cases; the combination detected 37 (84%). All 85 cases of cases of secondary and early latent infection were reactive in the TPHA test, whereas the VDRL was reactive in only 68 (80%). EIA had a reported sensitivity of 82% for primary infection.
CONCLUSIONS: EIA can be used as a single screening test for detecting early syphilis because its results are comparable with those of the combined VDRL and TPHA tests. The conventional VDRL test should not be used as a single screening test.
METHODS: Between 1980 and 1987 all serum samples were screened by both VDRL and TPHA tests. The FTA-ABS test was also used in suspected early primary syphilis, or when one of the other tests was positive. A positive result in a screening test was confirmed by quantitative testing. From 1988 all specimens were screened with an enzyme immunoassay (Captia Syph G) as a single screening test.
RESULTS: Of the 44 primary, 47 secondary, and 38 early latent cases of syphilis, the VDRL and TPHA detected 32 (73%) and 31 (71%) of the primary cases; the combination detected 37 (84%). All 85 cases of cases of secondary and early latent infection were reactive in the TPHA test, whereas the VDRL was reactive in only 68 (80%). EIA had a reported sensitivity of 82% for primary infection.
CONCLUSIONS: EIA can be used as a single screening test for detecting early syphilis because its results are comparable with those of the combined VDRL and TPHA tests. The conventional VDRL test should not be used as a single screening test.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app