Experience with the polymer-coated hydroxyapatite implant after enucleation in 126 patients.

Ophthalmology 2007 Februrary
OBJECTIVE: To evaluate the new polymer-coated hydroxyapatite implant.

DESIGN: Retrospective nonrandomized single-center case series.

PARTICIPANTS: One hundred twenty-six patients managed with enucleation and placement of the polymer-coated hydroxyapatite implant at the Ocular Oncology Service at Wills Eye Hospital of Thomas Jefferson University.

METHODS: A retrospective analysis was performed on 126 patients managed with enucleation and placement of the polymer-coated hydroxyapatite implant.

MAIN OUTCOME MEASURES: Ease of placement, functional ocular motility, tissue complications, and patient satisfaction.

RESULTS: The preenucleation diagnoses included uveal melanoma (n = 76; 61%), retinoblastoma (n = 34; 27%), blind painful eye (n = 8; 6%), neovascular glaucoma from intraocular tumors or retinal detachment (n = 5; 4%), and others (n = 3; 2%). Previous ocular therapies for posterior segment conditions such as plaque radiotherapy, retinal detachment repair, and chemoreduction, thermotherapy, and cryotherapy had been performed in 22% of patients (n = 27). The implant size was 20 mm (n = 103; 82%), 18 mm (n = 22; 17%), and 16 mm (n = 1; 1%). Implant preparation and placement was uncomplicated in all patients, without adhesion to surrounding tissue. Four rectus muscles were attached to the implant in all patients. Socket motility was judged to be good (n = 118; 94%), fair (n = 6; 5%), and poor (n = 2; 2%). Complications included conjunctival thinning (n = 1; <1%), pyogenic granuloma (n = 1; <1%), conjunctival cyst (n = 3; 2%), implant infection (n = 1; <1%), and implant exposure (n = 3; 2%). There were no cases of implant extrusion or allergic reaction to the polymer. Patient satisfaction was reported as good (n = 123; 98%), fair (n = 2; 2%), and poor (n = 1; <1%).

CONCLUSIONS: The polymer-coated hydroxyapatite implant is smoothly placed into the orbit after enucleation without the need for additional tissue wrap. With proper placement, this implant provides satisfactory functional motility and shows favorable tissue tolerance with no clinical evidence of allergic reaction or extrusion.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app